[Header]																		
Customer Name	"ILLUMINA, INC."																	
Product Type	ACP3																	
Date Manufactured	NA																	
Lot	NA																	
DesignStudio ID	NA																	
Target Plexity	212																	
																		
[Probes]																		
Target Region Name	Target Region ID	Target ID	Species	Build ID	Chromosome	Start Position	End Position	Submitted Target Region Strand	ULSO Sequence	ULSO Genomic Hits	DLSO Sequence	DLSO Genomic Hits	Probe Strand	Designer	Design Score	Expected Amplifed Region Size	SNP Masking	Labels
MPL1_2	MPL1_2.chr1.43815008.43815009	MPL1_2.chr1.43815008.43815009_tile_1	Homo sapiens	hg19	chr1	43815008	43815009	-	AAGTGGCGAAGCCGTAGGTGCGCACG	0	TCAGCAGCAGCAGGCCCAGGACGG	0	-	ILLUMINA	NA	183	TRUE	
NRAS1_7	NRAS1_7.chr1.115256528.115256531	NRAS1_7.chr1.115256528.115256531_tile_1	Homo sapiens	hg19	chr1	115256528	115256531	-	CAATAGCATTGCATTCCCTGTGGTTTT	0	AGAGTACAGTGCCATGAGAGACCAAT	0	-	ILLUMINA	NA	182	TRUE	
NRAS8_13	NRAS8_13.chr1.115258730.115258748	NRAS8_13.chr1.115258730.115258748_tile_1	Homo sapiens	hg19	chr1	115258730	115258748	-	GGGTTTTCATTTCCATTGATTATAGAAAG	0	CTGACAATCCAGCTAATCCAGAACCA	0	-	ILLUMINA	NA	184	TRUE	
ALK1	ALK1.chr2.29432664.29432664	ALK1.chr2.29432664.29432664_tile_1	Homo sapiens	hg19	chr2	29432664	29432664	-	GATAAAATCCTAGTGATGGCCGTTGTA	0	GACATCTACAGGTGAGTAAAGACTGCC	0	-	ILLUMINA	NA	188	TRUE	
ALK2	ALK2.chr2.29443695.29443695	ALK2.chr2.29443695.29443695_tile_1	Homo sapiens	hg19	chr2	29443695	29443695	-	TGCTGCCCATGTTTACAGAATGCCTT	0	CACCAGAACATTGTTCGCTGCATTG	0	-	ILLUMINA	NA	171	TRUE	
IDH1_1_2	IDH1_1_2.chr2.209113112.209113113	IDH1_1_2.chr2.209113112.209113113_tile_1	Homo sapiens	hg19	chr2	209113112	209113113	-	GAGGGTTGAGGAGTTCAAGTTGAAACA	0	CATGCTTATGGGGATCAAGTAAGTCAT	0	-	ILLUMINA	NA	182	TRUE	
ERBB4_1_2	ERBB4_1_2.chr2.212288942.212288955	ERBB4_1_2.chr2.212288942.212288955_tile_1	Homo sapiens	hg19	chr2	212288942	212288955	-	ACTACTGGTATAGTGCTGGTTTGTTCA	0	AGAACGTTTGCCTCAGCCTCCCATCTG	0	-	ILLUMINA	NA	190	TRUE	
ERBB4_3_4	ERBB4_3_4.chr2.212530066.212530135	ERBB4_3_4.chr2.212530066.212530135_tile_1	Homo sapiens	hg19	chr2	212530066	212530135	-	CATTTCAGGGTCCTGACAACTGTACAA	0	AACTGCACCCAAGGGTAAGCATTCTT	0	-	ILLUMINA	NA	176	TRUE	
ERBB4_5	ERBB4_5.chr2.212576857.212576857	ERBB4_5.chr2.212576857.212576857_tile_1	Homo sapiens	hg19	chr2	212576857	212576857	-	ATACTCTGCTATTTTATAATGAAGATGCAA	0	CCAGTAACATTGACAAATTCATAAACTGTA	0	-	ILLUMINA	NA	171	TRUE	
ERBB4_6_7	ERBB4_6_7.chr2.212578341.212578349	ERBB4_6_7.chr2.212578341.212578349_tile_1	Homo sapiens	hg19	chr2	212578341	212578349	-	AGGGTAAGATACATAAACACTATCAATGA	0	TGCCTGCCCTAGTTCCAAGATGGAA	0	-	ILLUMINA	NA	186	TRUE	
ERBB4_8	ERBB4_8.chr2.212587147.212587147	ERBB4_8.chr2.212587147.212587147_tile_1	Homo sapiens	hg19	chr2	212587147	212587147	-	TGAAAGTAATATTTGCTGTGTTGCAGG	0	CATTCTGTGTCAAGAAATGTCCACGTA	0	-	ILLUMINA	NA	172	TRUE	
ERBB4_9	ERBB4_9.chr2.212589811.212589811	ERBB4_9.chr2.212589811.212589811_tile_1	Homo sapiens	hg19	chr2	212589811	212589811	-	GCAGACTTTGATCATGGTCCTATCTCT	0	GACTGCTTTGTATGTCTGTGATTTCTC	0	-	ILLUMINA	NA	176	TRUE	
ERBB4_10	ERBB4_10.chr2.212652764.212652764	ERBB4_10.chr2.212652764.212652764_tile_1	Homo sapiens	hg19	chr2	212652764	212652764	-	AATGGTGGAGTCTATGTAGACCAGAAC	0	TCTTTTTAATTTCTCAAAATGTTCTACCCT	0	-	ILLUMINA	NA	172	TRUE	
ERBB4_11	ERBB4_11.chr2.212812157.212812157	ERBB4_11.chr2.212812157.212812157_tile_1	Homo sapiens	hg19	chr2	212812157	212812157	-	GTGGCTCTTAATCAGTTTCGTTACCTG	0	GGTAAGGAATATATCCAAAATGGCAAATA	0	-	ILLUMINA	NA	186	TRUE	
VHL1_2	VHL1_2.chr3.10183797.10183817	VHL1_2.chr3.10183797.10183817_tile_1	Homo sapiens	hg19	chr3	10183797	10183817	-	AAAATGGACCCCGGGGCGGTAGAGGG	0	ATACGGGCAGCACGACGCGCGGACT	0	-	ILLUMINA	NA	185	TRUE	
VHL3_5	VHL3_5.chr3.10188245.10188301	VHL3_5.chr3.10188245.10188301_tile_1	Homo sapiens	hg19	chr3	10188245	10188301	-	GAACTGGGCTTAATTTTTCAAGTGGTC	0	AGAAGCCCATCGTGTGTCCCTGCATCT	0	-	ILLUMINA	NA	186	TRUE	
VHL6_8	VHL6_8.chr3.10191480.10191506	VHL6_8.chr3.10191480.10191506_tile_1	Homo sapiens	hg19	chr3	10191480	10191506	-	TTGATGTGCAATGCGCTCCTGTGTCAG	0	GTATACACTGGAAGGGCAAAAACCAAAT	0	-	ILLUMINA	NA	186	TRUE	
MLH1	MLH1.chr3.37067240.37067240	MLH1.chr3.37067240.37067240_tile_1	Homo sapiens	hg19	chr3	37067240	37067240	-	TGGGAGTTCAAGCATCTCCTCATCTTG	0	ATCTGGTGGGCATAGACCTTATCACT	0	-	ILLUMINA	NA	184	TRUE	
CTNNB1_1_16	CTNNB1_1_16.chr3.41266040.41266137	CTNNB1_1_16.chr3.41266040.41266137_tile_1	Homo sapiens	hg19	chr3	41266040	41266137	-	GGTATCCACATCCTCTTCCTCAGGATT	0	GTCCAACTCCATCAAATCAGCTATAAA	0	-	ILLUMINA	NA	172	TRUE	
PIK3CA1	PIK3CA1.chr3.178916876.178916876	PIK3CA1.chr3.178916876.178916876_tile_1	Homo sapiens	hg19	chr3	178916876	178916876	-	AGGGACAACAGTTAAGCTTTATGGTTA	0	AAAAATTCTTCCCTTTCTGCTTCTTG	0	-	ILLUMINA	NA	190	TRUE	
PIK3CA2	PIK3CA2.chr3.178921553.178921553	PIK3CA2.chr3.178921553.178921553_tile_1	Homo sapiens	hg19	chr3	178921553	178921553	-	ACATTCGGAGATTTGGATGTTCTCCTA	0	TCACGTAGGTTGCACAAAGAATTTTTA	0	-	ILLUMINA	NA	186	TRUE	
PIK3CA3	PIK3CA3.chr3.178927980.178927980	PIK3CA3.chr3.178927980.178927980_tile_1	Homo sapiens	hg19	chr3	178927980	178927980	-	CTTCTAATCCATGAGGTACTGGCCAAA	0	AACACATTTCAAAACACTTTTCTTCCC	0	-	ILLUMINA	NA	178	TRUE	
PIK3CA4_11	PIK3CA4_11.chr3.178936074.178936095	PIK3CA4_11.chr3.178936074.178936095_tile_1	Homo sapiens	hg19	chr3	178936074	178936095	-	GGTATGGTAAAAACATGCTGAGATCAG	0	CTCGTGTAGAAATTGCTTTGAGCTGTT	0	-	ILLUMINA	NA	172	TRUE	
PIK3CA12	PIK3CA12.chr3.178938860.178938860	PIK3CA12.chr3.178938860.178938860_tile_1	Homo sapiens	hg19	chr3	178938860	178938860	-	TAAACAACTCTGCCCCACTGCAGTGAA	0	CTTCAAATACATCCCACATGCACGACA	0	-	ILLUMINA	NA	174	TRUE	
PIK3CA13_20	PIK3CA13_20.chr3.178952007.178952150	PIK3CA13_20.chr3.178952007.178952150_tile_1	Homo sapiens	hg19	chr3	178952007	178952150	-	CCAAAGCCTCTTGCTCAGTTTTATCTAA	0	AGCCTTGTAACACATCTCCTGAAACC	0	-	ILLUMINA	NA	175	TRUE	
PIK3CA13_20	PIK3CA13_20.chr3.178952007.178952150	PIK3CA13_20.chr3.178952007.178952150_tile_2	Homo sapiens	hg19	chr3	178952007	178952150	+	CATTGCATACATTCGAAAGACCCTAGC	0	AGATAACTGAGAAAATGAAAGCTCACTCTG	0	+	ILLUMINA	NA	187	TRUE	
FGFR3_1_2	FGFR3_1_2.chr4.1803564.1803568	FGFR3_1_2.chr4.1803564.1803568_tile_1	Homo sapiens	hg19	chr4	1803564	1803568	-	TTGCTGCCATTCACCTCCACGTGCTTG	0	TCTGTGGGGGCAGATGACGCTCAGG	0	-	ILLUMINA	NA	176	TRUE	
FGFR3_3_4	FGFR3_3_4.chr4.1806119.1806153	FGFR3_3_4.chr4.1806119.1806153_tile_1	Homo sapiens	hg19	chr4	1806119	1806153	-	GCTCAGAACCTGGTATCTACTTTCTGT	0	TAGCTGAGGATGCCTGCATACACACTG	0	-	ILLUMINA	NA	188	TRUE	
FGFR3_5_7	FGFR3_5_7.chr4.1807862.1807890	FGFR3_5_7.chr4.1807862.1807890_tile_1	Homo sapiens	hg19	chr4	1807862	1807890	-	AAACAAGGCCTCAGGCGCCATCCACT	0	GCCAGCCCGAAGTCTGCGATCT	0	-	ILLUMINA	NA	191	TRUE	
FGFR3_8	FGFR3_8.chr4.1808331.1808331	FGFR3_8.chr4.1808331.1808331_tile_1	Homo sapiens	hg19	chr4	1808331	1808331	-	CCGGAGGGACCCCCACCCCTGA	0	CCCCCAGCGTGAAGATCTCCCA	0	-	ILLUMINA	NA	171	TRUE	
FGFR3_9	FGFR3_9.chr4.1808949.1808949	FGFR3_9.chr4.1808949.1808949_tile_1	Homo sapiens	hg19	chr4	1808949	1808949	-	AAGCTCTGTGTAGCTGTCTCTCCATCT	0	TCGTGGGCAAACACGGAGTCGTC	0	-	ILLUMINA	NA	186	TRUE	
PDGFRA1_4	PDGFRA1_4.chr4.55141013.55141049	PDGFRA1_4.chr4.55141013.55141049_tile_1	Homo sapiens	hg19	chr4	55141013	55141049	-	TACCCCATGGAACTTACCAAGCACTAG	0	CTATAAATGACCAGGACAGGTAACTGG	0	-	ILLUMINA	NA	178	TRUE	
PDGFRA5	PDGFRA5.chr4.55144146.55144146	PDGFRA5.chr4.55144146.55144146_tile_1	Homo sapiens	hg19	chr4	55144146	55144146	-	GTCAGCTCCATTCAAGGGACTTCTATT	0	TACAATGTTCAAATGTGGCCCCAGGT	0	-	ILLUMINA	NA	188	TRUE	
PDGFRA6	PDGFRA6.chr4.55144547.55144547	PDGFRA6.chr4.55144547.55144547_tile_1	Homo sapiens	hg19	chr4	55144547	55144547	-	AACATCTCTCTTTGCACCCACCTCCGT	0	ATGATGTAAATGGGGCCTATGGGGAC	0	-	ILLUMINA	NA	186	TRUE	
PDGFRA7_23	PDGFRA7_23.chr4.55152040.55152109	PDGFRA7_23.chr4.55152040.55152109_tile_1	Homo sapiens	hg19	chr4	55152040	55152109	-	AGAGATTAAAGTGAAGGAGGATGAGCC	0	TTGCGAGCAGCCAGATCACGGTGGA	0	-	ILLUMINA	NA	174	TRUE	
KIT1	KIT1.chr4.55561764.55561764	KIT1.chr4.55561764.55561764_tile_1	Homo sapiens	hg19	chr4	55561764	55561764	-	GTGTTTGTTGGTGCACGTGTATTTGC	0	CCCACGCGGACTATTAAGTCTGATTTT	0	-	ILLUMINA	NA	179	TRUE	
KIT2	KIT2.chr4.55592185.55592186	KIT2.chr4.55592185.55592186_tile_1	Homo sapiens	hg19	chr4	55592185	55592186	-	CAGTATGGTGTGATGCATGTATTACCA	0	CAGAAGTCTTGCCCACATCGTTGTAA	0	-	ILLUMINA	NA	188	TRUE	
KIT3_19	KIT3_19.chr4.55593464.55593689	KIT3_19.chr4.55593464.55593689_tile_1	Homo sapiens	hg19	chr4	55593464	55593689	-	GAGAGAACAAATAAATGGTTACCTGTAAA	0	GTGGAATCACAAACTTTGGCAGGA	0	-	ILLUMINA	NA	172	TRUE	
KIT3_19	KIT3_19.chr4.55593464.55593689	KIT3_19.chr4.55593464.55593689_tile_2	Homo sapiens	hg19	chr4	55593464	55593689	+	CGTAGCTGGCATGATGTGCATTATTG	0	ACCCATGTATGAAGTACAGTGGAAGG	0	+	ILLUMINA	NA	175	TRUE	
KIT3_19	KIT3_19.chr4.55593464.55593689	KIT3_19.chr4.55593464.55593689_tile_3	Homo sapiens	hg19	chr4	55593464	55593689	-	GTGACATGGAAAGCCCCTGTTTCATA	0	TCTGTGGGGAGAAAGGGAAAAATAGAT	0	-	ILLUMINA	NA	185	TRUE	
KIT20_21	KIT20_21.chr4.55594221.55594258	KIT20_21.chr4.55594221.55594258_tile_1	Homo sapiens	hg19	chr4	55594221	55594258	-	GCAGTTTATAATCTAGCATTGCCAAAAT	0	AGTTCAGACATGAGGGCTTCCCGTTCT	0	-	ILLUMINA	NA	189	TRUE	
KIT22	KIT22.chr4.55595519.55595519	KIT22.chr4.55595519.55595519_tile_1	Homo sapiens	hg19	chr4	55595519	55595519	-	ACTATTTATGTAAATCAGTCTTACCAGGA	0	TAATGACCAGGGTGGGCCCTAAAAGC	0	-	ILLUMINA	NA	184	TRUE	
KIT23	KIT23.chr4.55597495.55597497	KIT23.chr4.55597495.55597497_tile_1	Homo sapiens	hg19	chr4	55597495	55597497	-	CCACATTAGCATGATATACATACTCTCT	0	CTGGGAGAGATGAAACAAGTCATGACT	0	-	ILLUMINA	NA	187	TRUE	
KIT24_28	KIT24_28.chr4.55599320.55599348	KIT24_28.chr4.55599320.55599348_tile_1	Homo sapiens	hg19	chr4	55599320	55599348	-	TGTGTGATATCCCTAGACAGGATTTAC	0	GGCTAGACCAAAATCACAAATCTTTGT	0	-	ILLUMINA	NA	184	TRUE	
KIT29	KIT29.chr4.55602694.55602694	KIT29.chr4.55602694.55602694_tile_1	Homo sapiens	hg19	chr4	55602694	55602694	-	GAAGCAGGACACCAATGAAACTTCAAG	0	TGCCATCCACTTCACAGGTAGTCGA	0	-	ILLUMINA	NA	186	TRUE	
KDR1	KDR1.chr4.55946114.55946257	KDR1.chr4.55946114.55946257_tile_1	Homo sapiens	hg19	chr4	55946114	55946257	-	ATTCTCCAGCCTGACTCGGGGACCACACTG	0	CATTTGATTTTCATTTCGACAACAGAAAAA	0	-	ILLUMINA	NA	173	TRUE	
KDR1	KDR1.chr4.55946114.55946257	KDR1.chr4.55946114.55946257_tile_2	Homo sapiens	hg19	chr4	55946114	55946257	+	ATGCTTCCTTTTAAACAGGAGGAGAGC	0	GGACTGGTAGCCGCTTGTCTGGTTTGA	0	+	ILLUMINA	NA	188	TRUE	
KDR3	KDR3.chr4.55953807.55953807	KDR3.chr4.55953807.55953807_tile_1	Homo sapiens	hg19	chr4	55953807	55953807	-	CTGAAGCCATAACAACAGTCTTCTGTG	0	ATTCCATTATGACAACACAGCAGGAAT	0	-	ILLUMINA	NA	190	TRUE	
KDR4	KDR4.chr4.55955111.55955127	KDR4.chr4.55955111.55955127_tile_1	Homo sapiens	hg19	chr4	55955111	55955127	-	TCCTTATTTAGCATCTCACCTCGTCAG	0	AGCCCAGTCAGAGACCCACGTTTT	0	-	ILLUMINA	NA	174	TRUE	
KDR6	KDR6.chr4.55960989.55961023	KDR6.chr4.55960989.55961023_tile_1	Homo sapiens	hg19	chr4	55960989	55961023	-	TTTATAGACCAAAGGGGCACGATTCCG	0	TGTAGAAGAAGAGGAAGGTACTGGCTA	0	-	ILLUMINA	NA	172	TRUE	
KDR8	KDR8.chr4.55962507.55962507	KDR8.chr4.55962507.55962507_tile_1	Homo sapiens	hg19	chr4	55962507	55962507	-	GGAAATGCATGTGGTCTGTAAACTAGG	0	AACACACAGTGAGCATCGAGCTCTCA	0	-	ILLUMINA	NA	178	TRUE	
KDR9	KDR9.chr4.55972964.55972964	KDR9.chr4.55972964.55972964_tile_1	Homo sapiens	hg19	chr4	55972964	55972964	-	TACCATGGTAGGCTGCGTTGGAAGTTA	0	GACAAACCCATACCCTTGTGAAGAATG	0	-	ILLUMINA	NA	172	TRUE	
KDR10	KDR10.chr4.55979623.55979623	KDR10.chr4.55979623.55979623_tile_1	Homo sapiens	hg19	chr4	55979623	55979623	-	CTGGTGTCCCTGTTTTTAGCATTAAAT	0	ACCTAAAAACCCAGTCTGGGAGTGAG	0	-	ILLUMINA	NA	182	TRUE	
KDR11	KDR11.chr4.55980348.55980348	KDR11.chr4.55980348.55980348_tile_1	Homo sapiens	hg19	chr4	55980348	55980348	-	TCTGTGCAAAGTTATAGGCTTATTTGC	0	AGAACTGAACTAAATGTGGGGATTGAC	0	-	ILLUMINA	NA	178	TRUE	
FBXW7_1	FBXW7_1.chr4.153245446.153245446	FBXW7_1.chr4.153245446.153245446_tile_1	Homo sapiens	hg19	chr4	153245446	153245446	-	CAGTAATTGATAGGAAGAGTATCCATACT	0	AACAAGTGGAATGGAACTCAAAGACAA	0	-	ILLUMINA	NA	190	TRUE	
FBXW7_2	FBXW7_2.chr4.153247288.153247366	FBXW7_2.chr4.153247288.153247366_tile_1	Homo sapiens	hg19	chr4	153247288	153247366	-	GTTTTGTTTTGTTTTTCTGTTTCTCCCT	0	TATGATGGCAGGAGGGTTGTTAGTGGAGCA	0	-	ILLUMINA	NA	171	TRUE	
FBXW7_5	FBXW7_5.chr4.153249384.153249384	FBXW7_5.chr4.153249384.153249384_tile_1	Homo sapiens	hg19	chr4	153249384	153249384	-	CATACAGGTGGAGTATGGTCATCACAA	0	AAAAGGTAAGGGAAAATCTTGTCATGG	0	-	ILLUMINA	NA	184	TRUE	
FBXW7_7	FBXW7_7.chr4.153250883.153250883	FBXW7_7.chr4.153250883.153250883_tile_1	Homo sapiens	hg19	chr4	153250883	153250883	-	CTGTTCCTGTTTATGCCTTCATTTTTC	0	AGTTAGTGGTTCTGATGACAACACTT	0	-	ILLUMINA	NA	180	TRUE	
FBXW7_8	FBXW7_8.chr4.153258983.153258983	FBXW7_8.chr4.153258983.153258983_tile_1	Homo sapiens	hg19	chr4	153258983	153258983	-	CTGTAATTTGGGACATCTGTTAAAACAATA	0	GACTTCATTTCATTGCTCCCTAAAGAGG	0	-	ILLUMINA	NA	191	TRUE	
APC1	APC1.chr5.112173917.112173917	APC1.chr5.112173917.112173917_tile_1	Homo sapiens	hg19	chr5	112173917	112173917	-	GCAGAGCTTCTTCTAAGTGCATTTCTC	0	TGAAGAAGTTCCTGGATTTTCTGTTGC	0	-	ILLUMINA	NA	186	TRUE	
APC2	APC2.chr5.112174631.112174631	APC2.chr5.112174631.112174631_tile_1	Homo sapiens	hg19	chr5	112174631	112174631	-	AATTTGTTGGTCTCTCTTCTTCTTCAT	0	TTTGTTTCTGAACCATTGGCTCCCCGT	0	-	ILLUMINA	NA	174	TRUE	
APC3_42	APC3_42.chr5.112175162.112175958	APC3_42.chr5.112175162.112175958_tile_1	Homo sapiens	hg19	chr5	112175162	112175958	+	CTTGCAAAGTTTCTTCTATTAACCAAGA	0	TTCTGCTAATACCCTGCAAATAGCAGA	0	+	ILLUMINA	NA	176	TRUE	
APC3_42	APC3_42.chr5.112175162.112175958	APC3_42.chr5.112175162.112175958_tile_2	Homo sapiens	hg19	chr5	112175162	112175958	-	TGCTGGATTTGGTTCTAGGGTGCT	0	CCTATTTCATCTTCAGCTGATGACAAA	0	-	ILLUMINA	NA	171	TRUE	
APC3_42	APC3_42.chr5.112175162.112175958	APC3_42.chr5.112175162.112175958_tile_3	Homo sapiens	hg19	chr5	112175162	112175958	+	GAAAAGATTGGAACTAGGTCAGCTGAAG	0	AGCGAAATCTCCCTCCAAAAGTGGT	0	+	ILLUMINA	NA	172	TRUE	
APC3_42	APC3_42.chr5.112175162.112175958	APC3_42.chr5.112175162.112175958_tile_4	Homo sapiens	hg19	chr5	112175162	112175958	-	CTATCAAGTGAACTGACAGAAGTACATC	0	CCTGGCTGATTCTGAAGATAAACTAGAACC	0	-	ILLUMINA	NA	171	TRUE	
APC3_42	APC3_42.chr5.112175162.112175958	APC3_42.chr5.112175162.112175958_tile_5	Homo sapiens	hg19	chr5	112175162	112175958	+	CACCCAAAAGTCCACCTGAACACTAT	0	ATTATAAGCCCCAGTGATCTTCCAGAT	0	+	ILLUMINA	NA	174	TRUE	
APC3_42	APC3_42.chr5.112175162.112175958	APC3_42.chr5.112175162.112175958_tile_6	Homo sapiens	hg19	chr5	112175162	112175958	-	CTCTCTCTTTTCAGCAGTAGGTGCTT	0	CACTTACCATTCCACTGCATGGTTCA	0	-	ILLUMINA	NA	173	TRUE	
APC3_42	APC3_42.chr5.112175162.112175958	APC3_42.chr5.112175162.112175958_tile_7	Homo sapiens	hg19	chr5	112175162	112175958	+	CAAACCAAGCGAGAAGTACCTAAAAAT	0	AAAGTACTCCAGATGGATTTTCTTGTTC	0	+	ILLUMINA	NA	171	TRUE	
APC3_42	APC3_42.chr5.112175162.112175958	APC3_42.chr5.112175162.112175958_tile_8	Homo sapiens	hg19	chr5	112175162	112175958	-	CTCTGATTCTGTTTCATTCCCATTGTCATT	0	GTGGCAAAATGTAATAAAGTATCAGCATCT	0	-	ILLUMINA	NA	173	TRUE	
APC3_42	APC3_42.chr5.112175162.112175958	APC3_42.chr5.112175162.112175958_tile_9	Homo sapiens	hg19	chr5	112175162	112175958	+	ATTAAGAATAATGCCTCCAGTTCAGGA	0	AGAAGAATGTATTATTTCTGCCATGCC	0	+	ILLUMINA	NA	190	TRUE	
CSF1R1_3	CSF1R1_3.chr5.149433644.149433646	CSF1R1_3.chr5.149433644.149433646_tile_1	Homo sapiens	hg19	chr5	149433644	149433646	-	TCCCACCCTCAGGACTATACCAATCT	0	AGTTCTGCTGAGGAGTTGACGACAGGG	0	-	ILLUMINA	NA	185	TRUE	
CSF1R4	CSF1R4.chr5.149453044.149453044	CSF1R4.chr5.149453044.149453044_tile_1	Homo sapiens	hg19	chr5	149453044	149453044	-	TCTTGGGTGGTGGGGACTATGTACCT	0	AACTTGAGCTCTGAGCAGAACCTCATC	0	-	ILLUMINA	NA	175	TRUE	
NPM1	NPM1.chr5.170837547.170837548	NPM1.chr5.170837547.170837548_tile_1	Homo sapiens	hg19	chr5	170837547	170837548	-	GGTAGGGAAAGTTCTCACTCTGCATTA	0	AAAAAGAAATGTGGTTAAGGAACCAC	0	-	ILLUMINA	NA	186	TRUE	
EGFR1	EGFR1.chr7.55211080.55211080	EGFR1.chr7.55211080.55211080_tile_1	Homo sapiens	hg19	chr7	55211080	55211080	-	CATCGGAACTGCTGTCTGCATTTATGA	0	GATGATCTGCAGGTTTTCCAAAGGAAT	0	-	ILLUMINA	NA	188	TRUE	
EGFR2	EGFR2.chr7.55221822.55221822	EGFR2.chr7.55221822.55221822_tile_1	Homo sapiens	hg19	chr7	55221822	55221822	-	AAGCAAGGCAAACACATCCACCCAAAG	0	AAAGCTGTATTTGCCCTCGGGGTTCA	0	-	ILLUMINA	NA	174	TRUE	
EGFR3	EGFR3.chr7.55233043.55233043	EGFR3.chr7.55233043.55233043_tile_1	Homo sapiens	hg19	chr7	55233043	55233043	-	AACTTGGGAGACATTTTTGATCTCTGA	0	TGCCGGGCAGGTCTTGACGCAGT	0	-	ILLUMINA	NA	186	TRUE	
EGFR4	EGFR4.chr7.55241677.55241708	EGFR4.chr7.55241677.55241708_tile_1	Homo sapiens	hg19	chr7	55241677	55241708	-	GGAAATATACAGCTTGCAAGGACTCTG	0	TCAAGATCCTCAAGAGAGCTTGGTTG	0	-	ILLUMINA	NA	180	TRUE	
EGFR9	EGFR9.chr7.55242418.55242511	EGFR9.chr7.55242418.55242511_tile_1	Homo sapiens	hg19	chr7	55242418	55242511	-	ATGAGAAAAGGTGGGCCTGAGGTTCAG	0	CCTATGACAGAGAGAGAAGGAAGACGTT	0	-	ILLUMINA	NA	190	TRUE	
EGFR44	EGFR44.chr7.55249005.55249131	EGFR44.chr7.55249005.55249131_tile_1	Homo sapiens	hg19	chr7	55249005	55249131	-	AGGTGAGGCAGATGCCCAGCAGGCGG	0	CGCATGAATGCGATCTTGAGTTTCAA	0	-	ILLUMINA	NA	175	TRUE	
EGFR44	EGFR44.chr7.55249005.55249131	EGFR44.chr7.55249005.55249131_tile_2	Homo sapiens	hg19	chr7	55249005	55249131	+	CAGCGTGGACAACCCCCACGTGT	0	GTGTGTGCAGATCGCAAAGGTAATCA	0	+	ILLUMINA	NA	177	TRUE	
EGFR54	EGFR54.chr7.55259514.55259524	EGFR54.chr7.55259514.55259524_tile_1	Homo sapiens	hg19	chr7	55259514	55259524	-	CCTCCCCTGCATGTGTTAAACAATACA	0	CCAAAATCTGTGATCTTGACATGCTGC	0	-	ILLUMINA	NA	178	TRUE	
MET1	MET1.chr7.116339642.116339642	MET1.chr7.116339642.116339642_tile_1	Homo sapiens	hg19	chr7	116339642	116339642	-	CCTTCTCACTGATATCGAATGCAATGG	0	CTTCTATCTGTGGGGAGAATATGCAGT	0	-	ILLUMINA	NA	180	TRUE	
MET2	MET2.chr7.116340262.116340262	MET2.chr7.116340262.116340262_tile_1	Homo sapiens	hg19	chr7	116340262	116340262	-	GCCCTGGATATTCTTTTTGAGACTGAT	0	GAAGAAGTCGTTGACATATTTGATAGG	0	-	ILLUMINA	NA	188	TRUE	
MET3	MET3.chr7.116411990.116411990	MET3.chr7.116411990.116411990_tile_1	Homo sapiens	hg19	chr7	116411990	116411990	-	TGCAAAACCAAAAATAAACAACAATGTC	0	TTACACTTCGGGCACTTACAAGCCTA	0	-	ILLUMINA	NA	171	TRUE	
MET4	MET4.chr7.116417463.116417464	MET4.chr7.116417463.116417464_tile_1	Homo sapiens	hg19	chr7	116417463	116417464	-	CACAAGGGGAAAGTGTAAATCAACGTTT	0	CACAACCAAAATGCCCTGTGCAAAAGA	0	-	ILLUMINA	NA	191	TRUE	
MET6	MET6.chr7.116423413.116423474	MET6.chr7.116423413.116423474_tile_1	Homo sapiens	hg19	chr7	116423413	116423474	-	GAGGAGAAACTCAGAGATAACCAATAC	0	TGTCTCTGGCAAGACCAAAATCAGCA	0	-	ILLUMINA	NA	172	TRUE	
SMO1	SMO1.chr7.128845101.128845101	SMO1.chr7.128845101.128845101_tile_1	Homo sapiens	hg19	chr7	128845101	128845101	-	TGACCAGGGTGAAGAGCGTGCAGAG	0	AAGGGCACTTCGCACTGGCCTGAA	0	-	ILLUMINA	NA	186	TRUE	
SMO2	SMO2.chr7.128846040.128846040	SMO2.chr7.128846040.128846040_tile_1	Homo sapiens	hg19	chr7	128846040	128846040	-	ATTGCCACAGTGAGGACAAAGGGGAGT	0	GTACACGATGACAAAGATGATGACGCA	0	-	ILLUMINA	NA	186	TRUE	
SMO3	SMO3.chr7.128846374.128846374	SMO3.chr7.128846374.128846374_tile_1	Homo sapiens	hg19	chr7	128846374	128846374	-	TAGCTGGGGTTTCAGCATGGGGGCAGC	0	AAGCCCGCACGGTATCGGTAGTTCT	0	-	ILLUMINA	NA	190	TRUE	
SMO4	SMO4.chr7.128850341.128850341	SMO4.chr7.128850341.128850341_tile_1	Homo sapiens	hg19	chr7	128850341	128850341	-	AACCACTGACCAAGGCTGTGCTAGAGG	0	TCATGGCGATGCCAGTTCCAAACA	0	-	ILLUMINA	NA	190	TRUE	
SMO5	SMO5.chr7.128851593.128851593	SMO5.chr7.128851593.128851593_tile_1	Homo sapiens	hg19	chr7	128851593	128851593	-	TTCAGATCCTCTGGGGCCTTTCCTTC	0	AGAAATATCCTGGGGCAGTATGGCTCC	0	-	ILLUMINA	NA	173	TRUE	
BRAF1	BRAF1.chr7.140453121.140453193	BRAF1.chr7.140453121.140453193_tile_1	Homo sapiens	hg19	chr7	140453121	140453193	-	ACCTAAACTCTTCATAATGCTTGCTCT	0	GGTCCCATCAGTTTGAACAGTTGTCT	0	-	ILLUMINA	NA	176	TRUE	
BRAF28	BRAF28.chr7.140481397.140481478	BRAF28.chr7.140481397.140481478_tile_1	Homo sapiens	hg19	chr7	140481397	140481478	-	GGTTTTCTTTTTCTGTTTGGCTTGACT	0	CTACAAGGGAAAGTGGCATGGTAAGTA	0	-	ILLUMINA	NA	178	TRUE	
FGFR1_1	FGFR1_1.chr8.38282209.38282209	FGFR1_1.chr8.38282209.38282209_tile_1	Homo sapiens	hg19	chr8	38282209	38282209	-	TTTTGAGAGGCTTGGGCTCAGCAGAA	0	TCACCGGCCCATCCTGCAAGCAGGG	0	-	ILLUMINA	NA	179	TRUE	
FGFR1_2	FGFR1_2.chr8.38285938.38285938	FGFR1_2.chr8.38285938.38285938_tile_1	Homo sapiens	hg19	chr8	38285938	38285938	-	AAGAGATCATCACTAAGGGAGCAGTGG	0	GGATGATGATGATGATGATGACTCCTC	0	-	ILLUMINA	NA	184	TRUE	
JAK2_1	JAK2_1.chr9.5073769.5073770	JAK2_1.chr9.5073769.5073770_tile_1	Homo sapiens	hg19	chr9	5073769	5073770	-	TTCAGTTTCAAAAATACTTAACTCCTGTT	0	CTCCATAATTTAAAACCAAATGCTTGTG	0	-	ILLUMINA	NA	188	TRUE	
CDKN2A1	CDKN2A1.chr9.21971153.21971187	CDKN2A1.chr9.21971153.21971187_tile_1	Homo sapiens	hg19	chr9	21971153	21971187	-	TTGTGTGGGGGTCTGCTTGGCGGTGA	0	AACTGCGCCGACCCCGCCACTCTCA	0	-	ILLUMINA	NA	187	TRUE	
ABL1_1	ABL1_1.chr9.133738330.133738364	ABL1_1.chr9.133738330.133738364_tile_1	Homo sapiens	hg19	chr9	133738330	133738364	-	ATGCATCGCCTAATGCCAGCAGACGC	0	TGATGTCCGTGCGTTCCATCTCCCAC	0	-	ILLUMINA	NA	191	TRUE	
ABL1_9	ABL1_9.chr9.133747520.133747520	ABL1_9.chr9.133747520.133747520_tile_1	Homo sapiens	hg19	chr9	133747520	133747520	-	AGCGCCTGTGTCACCCTGGGGGT	0	AAAACGAAGGTGAAATTATTTCAGGAA	0	-	ILLUMINA	NA	190	TRUE	
ABL1_10	ABL1_10.chr9.133748283.133748414	ABL1_10.chr9.133748283.133748414_tile_1	Homo sapiens	hg19	chr9	133748283	133748414	+	AGAATCCTTCAGAAGGCTTTTTCTTTAGAC	0	AACCTCCTGGACTACCTGAGGGAGT	0	+	ILLUMINA	NA	172	TRUE	
ABL1_10	ABL1_10.chr9.133748283.133748414	ABL1_10.chr9.133748283.133748414_tile_2	Homo sapiens	hg19	chr9	133748283	133748414	-	TCCATGGCGCAGGCTGCCTGGCC	0	CCGTAGGTCATGAACTCAGTGATGA	0	-	ILLUMINA	NA	182	TRUE	
ABL1_16	ABL1_16.chr9.133750356.133750356	ABL1_16.chr9.133750356.133750356_tile_1	Homo sapiens	hg19	chr9	133750356	133750356	-	GGGAAGAGCAAGAAAGAGGCAGAAAAA	0	TGTGTAGGTGTCCCCTGTCATCAA	0	-	ILLUMINA	NA	190	TRUE	
NOTCH1_1	NOTCH1_1.chr9.139397768.139397768	NOTCH1_1.chr9.139397768.139397768_tile_1	Homo sapiens	hg19	chr9	139397768	139397768	-	AGACCTGGCTTCCCACCACCCCAGGCT	0	AGATTGACAACCGGCAGTGTGTGCAG	0	-	ILLUMINA	NA	190	TRUE	
NOTCH1_2	NOTCH1_2.chr9.139399344.139399422	NOTCH1_2.chr9.139399344.139399422_tile_1	Homo sapiens	hg19	chr9	139399344	139399422	-	AGTGCGAGTGGGACGGGCTGGACTGT	0	ACACCAACGTGGTCTTCAAGCGTGAC	0	-	ILLUMINA	NA	171	TRUE	
RET1	RET1.chr10.43609078.43609104	RET1.chr10.43609078.43609104_tile_1	Homo sapiens	hg19	chr10	43609078	43609104	-	ACTCGCCTCCCAGCAATTTCCTCCC	0	TTGCAGGTGCCATAGCCAGCTTTAAT	0	-	ILLUMINA	NA	180	TRUE	
RET2_9	RET2_9.chr10.43609940.43609950	RET2_9.chr10.43609940.43609950_tile_1	Homo sapiens	hg19	chr10	43609940	43609950	+	AAGCCTCACACCACCCCCACCCACAGAT	0	CCCATCTCCTCAGCTGAGATGACCTT	0	+	ILLUMINA	NA	175	TRUE	
RET10	RET10.chr10.43613840.43613840	RET10.chr10.43613840.43613840_tile_1	Homo sapiens	hg19	chr10	43613840	43613840	-	AGAACAGGGCTGTATGGAGCCCCCAGC	0	GGGAGGCGTTCTCTGAAATGCAG	0	-	ILLUMINA	NA	190	TRUE	
RET11_12	RET11_12.chr10.43615567.43615569	RET11_12.chr10.43615567.43615569_tile_1	Homo sapiens	hg19	chr10	43615567	43615569	-	ATGGTGCACCTGGGATCCCTGGGAG	0	ATGTTTCTGGCTGCCAAGTCCCGATGAA	0	-	ILLUMINA	NA	172	TRUE	
RET13	RET13.chr10.43617416.43617416	RET13.chr10.43617416.43617416_tile_1	Homo sapiens	hg19	chr10	43617416	43617416	-	AATTCCCTGGCCAAGCTGCACAGACGG	0	CCATTTAACTGGAATCCGACCCTAAAG	0	-	ILLUMINA	NA	178	TRUE	
PTEN1	PTEN1.chr10.89624242.89624244	PTEN1.chr10.89624242.89624244_tile_1	Homo sapiens	hg19	chr10	89624242	89624244	-	TACGGACATTTTCGCATCCGTCTACTC	0	ATGATGGCTGTCATGTCTGGGAGCCTG	0	-	ILLUMINA	NA	176	TRUE	
PTEN3	PTEN3.chr10.89685307.89685307	PTEN3.chr10.89685307.89685307_tile_1	Homo sapiens	hg19	chr10	89685307	89685307	-	TGGACTTCTTGACTTAATCGGTTTAGG	0	CTTGTAATGGTTTTTATGCTTTGAATCCA	0	-	ILLUMINA	NA	186	TRUE	
PTEN4	PTEN4.chr10.89711893.89711900	PTEN4.chr10.89711893.89711900_tile_1	Homo sapiens	hg19	chr10	89711893	89711900	-	GGATGAGAATTTCAAGCACTTACTGCA	0	TGGGAATAGTTACTCCCTGGTGGACA	0	-	ILLUMINA	NA	176	TRUE	
PTEN7	PTEN7.chr10.89717615.89717772	PTEN7.chr10.89717615.89717772_tile_1	Homo sapiens	hg19	chr10	89717615	89717772	-	GGGTCCTGAATTGGAGGAATATATCTTCAC	0	ACACGAAATATGGATTCTGTATCTGC	0	-	ILLUMINA	NA	181	TRUE	
PTEN7	PTEN7.chr10.89717615.89717772	PTEN7.chr10.89717615.89717772_tile_2	Homo sapiens	hg19	chr10	89717615	89717772	+	CAGTTTGTGGTCTGCCAGCTAAA	0	AAAGGTTTGTACTTTACTTTCATTGGGAG	0	+	ILLUMINA	NA	188	TRUE	
PTEN13	PTEN13.chr10.89720716.89720852	PTEN13.chr10.89720716.89720852_tile_1	Homo sapiens	hg19	chr10	89720716	89720852	-	AATTTGGAGAAAAGTATCGGTTGGCTT	0	AGGTTTCCTCTGGTCCTGGTATGAA	0	-	ILLUMINA	NA	188	TRUE	
PTEN13	PTEN13.chr10.89720716.89720852	PTEN13.chr10.89720716.89720852_tile_2	Homo sapiens	hg19	chr10	89720716	89720852	+	AAAATGATCTTGACAAAGCAAATAAAGAC	0	CTTGCTTGACAAGTTTTTAACTTATGTATT	0	+	ILLUMINA	NA	179	TRUE	
FGFR2_1	FGFR2_1.chr10.123258034.123258034	FGFR2_1.chr10.123258034.123258034_tile_1	Homo sapiens	hg19	chr10	123258034	123258034	-	CTAACAGTAGCTGCCCATGAGTTAGAG	0	TTCTTGGAGCCTGCACACAGGATGGTG	0	-	ILLUMINA	NA	180	TRUE	
FGFR2_2	FGFR2_2.chr10.123274774.123274803	FGFR2_2.chr10.123274774.123274803_tile_1	Homo sapiens	hg19	chr10	123274774	123274803	-	GCCTTTTGGTTCCTTTGGTTGTGCTAT	0	CATAGGGGTCTTCTTAATCGCCTGTAT	0	-	ILLUMINA	NA	186	TRUE	
FGFR2_5	FGFR2_5.chr10.123279503.123279677	FGFR2_5.chr10.123279503.123279677_tile_1	Homo sapiens	hg19	chr10	123279503	123279677	-	CACGTGGAAAAGAACGGCAGTAAATAC	0	GGAGTTGAGAGAGGATGATTCTCTTTT	0	-	ILLUMINA	NA	172	TRUE	
FGFR2_5	FGFR2_5.chr10.123279503.123279677	FGFR2_5.chr10.123279503.123279677_tile_2	Homo sapiens	hg19	chr10	123279503	123279677	+	TTTAGATTCAGAAAGTCCTCACCTTGAG	0	CTCCTCCGACCACTGTGGAGGCATTT	0	+	ILLUMINA	NA	171	TRUE	
FGFR2_5	FGFR2_5.chr10.123279503.123279677	FGFR2_5.chr10.123279503.123279677_tile_3	Homo sapiens	hg19	chr10	123279503	123279677	-	ACTGACAGCCCTCTGGACAACACAGCT	0	CGTAGAGTTTGTCTGCAAGGTTTACAG	0	-	ILLUMINA	NA	184	TRUE	
HRAS1	HRAS1.chr11.533873.533875	HRAS1.chr11.533873.533875_tile_1	Homo sapiens	hg19	chr11	533873	533875	-	TACCAGGGAGAGGCTGGCTGTGTGAAC	0	AGTACAGCGCCATGCGGGACCAGTAC	0	-	ILLUMINA	NA	180	TRUE	
HRAS6	HRAS6.chr11.534285.534289	HRAS6.chr11.534285.534289_tile_1	Homo sapiens	hg19	chr11	534285	534289	-	CTGCCCTGTGGGGCCTGGGGCTGG	0	AAGAGTGCGCTGACCATCCAGCTGATC	0	-	ILLUMINA	NA	185	TRUE	
ATM1	ATM1.chr11.108117847.108117848	ATM1.chr11.108117847.108117848_tile_1	Homo sapiens	hg19	chr11	108117847	108117848	-	GAAAGGAATAGTTGCATGTACAGAGTC	0	GATATCTGCCATCAATTCAATCAAATTTT	0	-	ILLUMINA	NA	174	TRUE	
ATM2	ATM2.chr11.108119823.108119823	ATM2.chr11.108119823.108119823_tile_1	Homo sapiens	hg19	chr11	108119823	108119823	-	TTGCTAGTAATAGGTTTGGGGGTAGAC	0	GATCAAAATCATTCTGTGACTTCTGAA	0	-	ILLUMINA	NA	172	TRUE	
ATM3	ATM3.chr11.108123551.108123551	ATM3.chr11.108123551.108123551_tile_1	Homo sapiens	hg19	chr11	108123551	108123551	-	AAGCTATAGCTTAAAATGATAAAGAGCAT	0	ACAAAGAAAAACAAAAAGCTTCACTTAGA	0	-	ILLUMINA	NA	172	TRUE	
ATM4	ATM4.chr11.108137973.108138003	ATM4.chr11.108137973.108138003_tile_1	Homo sapiens	hg19	chr11	108137973	108138003	-	ACTGCCAAATCAATATAAAGAAGTAAAAGA	0	GATTTCCATTAGTATCATCTTCCATTGAT	0	-	ILLUMINA	NA	189	TRUE	
ATM6	ATM6.chr11.108155132.108155132	ATM6.chr11.108155132.108155132_tile_1	Homo sapiens	hg19	chr11	108155132	108155132	-	TCGAATAAATAGCCTTAAAACTTAAAGGTT	0	ATCCCACTGTCTCTGGTACCCTCATAG	0	-	ILLUMINA	NA	179	TRUE	
ATM7	ATM7.chr11.108170476.108170479	ATM7.chr11.108170476.108170479_tile_1	Homo sapiens	hg19	chr11	108170476	108170479	-	ACTCACCAATCTTCTACCAGTGTGTTA	0	ACTTCTCCCAAGCAGCTTCCAACAGCC	0	-	ILLUMINA	NA	178	TRUE	
ATM9	ATM9.chr11.108172421.108172421	ATM9.chr11.108172421.108172421_tile_1	Homo sapiens	hg19	chr11	108172421	108172421	-	ACAGAACTGTTTTAGATATGCTGGGTA	0	AATGTTTTTCAAACAGGTAACAGCTGC	0	-	ILLUMINA	NA	182	TRUE	
ATM10	ATM10.chr11.108173640.108173640	ATM10.chr11.108173640.108173640_tile_1	Homo sapiens	hg19	chr11	108173640	108173640	-	CAGGTCATAAACAAGGAATTATATCAGACT	0	ATATCATCCAGGCCTTCAAAAGGG	0	-	ILLUMINA	NA	191	TRUE	
ATM11	ATM11.chr11.108180945.108180945	ATM11.chr11.108180945.108180945_tile_1	Homo sapiens	hg19	chr11	108180945	108180945	-	CCCTTATTGAGACAATGCCAACATTAA	0	CTAGATAATTTAAATCCAGCCAGAAAGC	0	-	ILLUMINA	NA	188	TRUE	
ATM12	ATM12.chr11.108200958.108200961	ATM12.chr11.108200958.108200961_tile_1	Homo sapiens	hg19	chr11	108200958	108200961	-	CAAAGTCGGAATACCCACATATCATGT	0	CCTTTACTGTGTATCTTGCATAGAATAAT	0	-	ILLUMINA	NA	172	TRUE	
ATM14	ATM14.chr11.108204681.108204681	ATM14.chr11.108204681.108204681_tile_1	Homo sapiens	hg19	chr11	108204681	108204681	-	TAGGTTGAAACATATGAAATTTGCCAA	0	GGGACAACAACATCTTCTAAATTCTTAAG	0	-	ILLUMINA	NA	174	TRUE	
ATM15	ATM15.chr11.108205769.108205769	ATM15.chr11.108205769.108205769_tile_1	Homo sapiens	hg19	chr11	108205769	108205769	-	GACAAAATCCCAAATAAAGCAGAAAGAA	0	CCTGCTAAGCGAAATTCTGCTTTAAATG	0	-	ILLUMINA	NA	191	TRUE	
ATM16	ATM16.chr11.108206594.108206594	ATM16.chr11.108206594.108206594_tile_1	Homo sapiens	hg19	chr11	108206594	108206594	-	CACCCAACCAAATGGCATCTTTTATAT	0	TTGTCTCAGGTCATCACGGCCCTTCAG	0	-	ILLUMINA	NA	186	TRUE	
ATM17	ATM17.chr11.108218089.108218089	ATM17.chr11.108218089.108218089_tile_1	Homo sapiens	hg19	chr11	108218089	108218089	-	CTAGGACAACTGTTTATGCTGAAAACA	0	TCTATATGTACAAGTTCTGCTGACTGC	0	-	ILLUMINA	NA	188	TRUE	
ATM18	ATM18.chr11.108225590.108225590	ATM18.chr11.108225590.108225590_tile_1	Homo sapiens	hg19	chr11	108225590	108225590	-	GCTAAGTGCACAATCTCCTCCTTTCT	0	AACAGAGTTTCCTGAGAGTTTCTCATC	0	-	ILLUMINA	NA	191	TRUE	
ATM19	ATM19.chr11.108236086.108236203	ATM19.chr11.108236086.108236203_tile_1	Homo sapiens	hg19	chr11	108236086	108236203	-	TGAAGATCACACCCAAGCTTTCCATC	0	TCAGCTACTTTGTTGAAACTCTGGTCA	0	-	ILLUMINA	NA	185	TRUE	
KRAS1	KRAS1.chr12.25378562.25378562	KRAS1.chr12.25378562.25378562_tile_1	Homo sapiens	hg19	chr12	25378562	25378562	-	TCTTTCCCAGAGAACAAATTAAAAGAGT	0	AGACAAGACAGGTAAGTAACACTGAAA	0	-	ILLUMINA	NA	187	TRUE	
KRAS2	KRAS2.chr12.25380275.25380283	KRAS2.chr12.25380275.25380283_tile_1	Homo sapiens	hg19	chr12	25380275	25380283	-	TTGTTGTTGAGTTGTATATAACACCTTTT	0	AGTACAGTGCAATGAGGGACCAGTAC	0	-	ILLUMINA	NA	184	TRUE	
KRAS7	KRAS7.chr12.25398255.25398285	KRAS7.chr12.25398255.25398285_tile_1	Homo sapiens	hg19	chr12	25398255	25398285	-	GGTACTGGTGGAGTATTTGATAGTGTAT	0	GCTAATTCAGAATCATTTTGTGGACGAAT	0	-	ILLUMINA	NA	191	TRUE	
PTPN11_1	PTPN11_1.chr12.112888163.112888211	PTPN11_1.chr12.112888163.112888211_tile_1	Homo sapiens	hg19	chr12	112888163	112888211	-	TACTGACCTTTCAGAGGTAGGATCTGC	0	GTGTTCTGAATCTTGATGTGGGTGAC	0	-	ILLUMINA	NA	190	TRUE	
PTPN11_10	PTPN11_10.chr12.112926884.112926888	PTPN11_10.chr12.112926884.112926888_tile_1	Homo sapiens	hg19	chr12	112926884	112926888	-	CAAGAGGCCTAGCAAGAGAATGAGAAT	0	TCTGAGACCGCACCATCTGGATGGTT	0	-	ILLUMINA	NA	178	TRUE	
HNF1A_1	HNF1A_1.chr12.121431413.121431414	HNF1A_1.chr12.121431413.121431414_tile_1	Homo sapiens	hg19	chr12	121431413	121431414	-	TTGCCGCAGCCCAGACCAAACCAGCA	0	TTGAAACGGTTCCTCCGCCCCTTCTT	0	-	ILLUMINA	NA	175	TRUE	
HNF1A_3	HNF1A_3.chr12.121432070.121432070	HNF1A_3.chr12.121432070.121432070_tile_1	Homo sapiens	hg19	chr12	121432070	121432070	-	ACATACCACTTACCGTGGACCTTACT	0	CGGTTGGCAAACCAGTTGTAGACA	0	-	ILLUMINA	NA	181	TRUE	
FLT3_1	FLT3_1.chr13.28592620.28592653	FLT3_1.chr13.28592620.28592653_tile_1	Homo sapiens	hg19	chr13	28592620	28592653	-	CACATCACAGTAAATAACACTCTGGTG	0	TTGTCAGGGGCAATGTGAGGCTGCTATT	0	-	ILLUMINA	NA	178	TRUE	
FLT3_13	FLT3_13.chr13.28602329.28602329	FLT3_13.chr13.28602329.28602329_tile_1	Homo sapiens	hg19	chr13	28602329	28602329	-	ACTTGAGTTTTACATTTTTAATGCTCCT	0	TGTCAGGTAACCCACTTCCACGAAAA	0	-	ILLUMINA	NA	171	TRUE	
FLT3_14	FLT3_14.chr13.28608244.28608341	FLT3_14.chr13.28608244.28608341_tile_1	Homo sapiens	hg19	chr13	28608244	28608341	-	CTATCTGCAGAACTGCCTATTCCTAAC	0	TTCCAAGAGAAAATTTAGAGTTTGGTAAG	0	-	ILLUMINA	NA	190	TRUE	
FLT3_22	FLT3_22.chr13.28610138.28610138	FLT3_22.chr13.28610138.28610138_tile_1	Homo sapiens	hg19	chr13	28610138	28610138	+	CCAGGTCCAAGATGGTAATGGGTAT	0	ATACCAATACTTTGTGAAGCCAAGGTGG	0	+	ILLUMINA	NA	171	TRUE	
RB1_1	RB1_1.chr13.48919244.48919244	RB1_1.chr13.48919244.48919244_tile_1	Homo sapiens	hg19	chr13	48919244	48919244	-	CCTTTCCAATTTGCTGAAGAGTGCAAA	0	CAGTAACCTTAAAAATTTGTGTTATTTCGT	0	-	ILLUMINA	NA	182	TRUE	
RB1_2	RB1_2.chr13.48923148.48923148	RB1_2.chr13.48923148.48923148_tile_1	Homo sapiens	hg19	chr13	48923148	48923148	-	GCTAACAGTTAATAAGCCAAGCAGAGA	0	AAATGTGATCCAAGAAACTTTTAGCAC	0	-	ILLUMINA	NA	178	TRUE	
RB1_3	RB1_3.chr13.48942685.48942685	RB1_3.chr13.48942685.48942685_tile_1	Homo sapiens	hg19	chr13	48942685	48942685	-	ACATAAAGAAACGTGAACAAATCTGAAA	0	GGTGTTCTCTGTGTTTCAAAACTAAATAA	0	-	ILLUMINA	NA	173	TRUE	
RB1_4	RB1_4.chr13.48955538.48955550	RB1_4.chr13.48955538.48955550_tile_1	Homo sapiens	hg19	chr13	48955538	48955550	-	TTCCCTATATGTTCTTGAGGTAGATGT	0	AATGTTTTATCATTTCTCTTGTCAAGTTG	0	-	ILLUMINA	NA	182	TRUE	
RB1_6	RB1_6.chr13.49027168.49027168	RB1_6.chr13.49027168.49027168_tile_1	Homo sapiens	hg19	chr13	49027168	49027168	-	TTTGCAGTTTGAATGGTCAACATAACA	0	TAAAGGTGAATCCTATATGAAACATGATG	0	-	ILLUMINA	NA	178	TRUE	
RB1_7	RB1_7.chr13.49033843.49033846	RB1_7.chr13.49033843.49033846_tile_1	Homo sapiens	hg19	chr13	49033843	49033846	-	GAAGTGCTTGATTTTCTTACTTGGTCC	0	TAGGCTAGCCGATACACTGTGGGAATA	0	-	ILLUMINA	NA	178	TRUE	
RB1_8	RB1_8.chr13.49037877.49037877	RB1_8.chr13.49037877.49037877_tile_1	Homo sapiens	hg19	chr13	49037877	49037877	-	GGAAAATTACCTACCTCCTGAACAGCA	0	AGTAGTCAGAATTTTATTACATGGTTTTGT	0	-	ILLUMINA	NA	172	TRUE	
RB1_9	RB1_9.chr13.49039164.49039164	RB1_9.chr13.49039164.49039164_tile_1	Homo sapiens	hg19	chr13	49039164	49039164	-	TGTTTTGGTGGACCCATTACATTAGAT	0	CTTTGATCAAAACACGTTTGAATGTCT	0	-	ILLUMINA	NA	174	TRUE	
AKT1	AKT1.chr14.105246455.105246455	AKT1.chr14.105246455.105246455_tile_1	Homo sapiens	hg19	chr14	105246455	105246455	-	TCTGACGGGTAGAGTGTGCGTGGCTC	0	GCTCCCCTCAACAACTTCTCTGTG	0	-	ILLUMINA	NA	173	TRUE	
CDH1_1	CDH1_1.chr16.68835649.68835650	CDH1_1.chr16.68835649.68835650_tile_1	Homo sapiens	hg19	chr16	68835649	68835650	-	GGCGGTGGTGGTGCCCCACTGT	0	CTTTGAATCGGGTGTCGAGGGAAAAA	0	-	ILLUMINA	NA	171	TRUE	
CDH1_2	CDH1_2.chr16.68846137.68846137	CDH1_2.chr16.68846137.68846137_tile_1	Homo sapiens	hg19	chr16	68846137	68846137	-	ACATTCTCTAGTCTGGAGAGAGTTTTC	0	TTGGTGTCAGTGACTGTGATCACAGCT	0	-	ILLUMINA	NA	176	TRUE	
CDH1_3	CDH1_3.chr16.68847274.68847277	CDH1_3.chr16.68847274.68847277_tile_1	Homo sapiens	hg19	chr16	68847274	68847277	-	CATCTTGCCAGGTACCATACAAACCTT	0	CACTTTCAGTGTGGTGATTACGACGTT	0	-	ILLUMINA	NA	178	TRUE	
TP53_1	TP53_1.chr17.7574003.7574021	TP53_1.chr17.7574003.7574021_tile_1	Homo sapiens	hg19	chr17	7574003	7574021	-	ACTAAATGCATGTTGCTTTTGTACCGT	0	AGAGCTGAATGAGGCCTTGGAACTC	0	-	ILLUMINA	NA	172	TRUE	
TP53_3	TP53_3.chr17.7577022.7577129	TP53_3.chr17.7577022.7577129_tile_1	Homo sapiens	hg19	chr17	7577022	7577129	-	ATCCTGAGTAGTGGTAATCTACTGGGA	0	AGGTAAGCAAGCAGGACAAGAAGCG	0	-	ILLUMINA	NA	172	TRUE	
TP53_17	TP53_17.chr17.7577523.7577574	TP53_17.chr17.7577523.7577574_tile_1	Homo sapiens	hg19	chr17	7577523	7577574	-	AAAAAGGCCTCCCCTGCTTGCCACAGG	0	ATCATCACACTGGAAGACTCCAGGTCA	0	-	ILLUMINA	NA	190	TRUE	
TP53_31_59	TP53_31_59.chr17.7578190.7578536	TP53_31_59.chr17.7578190.7578536_tile_1	Homo sapiens	hg19	chr17	7578190	7578536	-	TTTGGATGACAGAAACACTTTTCGACA	0	CCTGCTGCTTATTTGACCTCCCTATAAC	0	-	ILLUMINA	NA	172	TRUE	
TP53_31_59	TP53_31_59.chr17.7578190.7578536	TP53_31_59.chr17.7578190.7578536_tile_2	Homo sapiens	hg19	chr17	7578190	7578536	+	GACCCCAGTTGCAAACCAGACCTCA	0	TGAGGAATCAGAGGCCTGGGGA	0	+	ILLUMINA	NA	171	TRUE	
TP53_31_59	TP53_31_59.chr17.7578190.7578536	TP53_31_59.chr17.7578190.7578536_tile_3	Homo sapiens	hg19	chr17	7578190	7578536	-	TTGTGAGGCGCTGCCCCCACCATGAG	0	GCATCTTATCCGAGTGGAAGGAAATTTG	0	-	ILLUMINA	NA	171	TRUE	
TP53_31_59	TP53_31_59.chr17.7578190.7578536	TP53_31_59.chr17.7578190.7578536_tile_4	Homo sapiens	hg19	chr17	7578190	7578536	+	CGTCTCTCCAGCCCCAGCTGCTCACCAT	0	CCACAGCTGCACAGGGCAGGTCTT	0	+	ILLUMINA	NA	171	TRUE	
TP53_31_59	TP53_31_59.chr17.7578190.7578536	TP53_31_59.chr17.7578190.7578536_tile_5	Homo sapiens	hg19	chr17	7578190	7578536	-	GCATGTTTGTTTCTTTGCTGCCGTCT	0	TTGATTCCACACCCCCGCCCGGC	0	-	ILLUMINA	NA	179	TRUE	
TP53_60	TP53_60.chr17.7579358.7579403	TP53_60.chr17.7579358.7579403_tile_1	Homo sapiens	hg19	chr17	7579358	7579403	-	AGATGAAGCTCCCAGAATGCCAGAGG	0	TTCTTGCATTCTGGGACAGCCAAGTCT	0	-	ILLUMINA	NA	185	TRUE	
TP53_64	TP53_64.chr17.7579882.7579882	TP53_64.chr17.7579882.7579882_tile_1	Homo sapiens	hg19	chr17	7579882	7579882	-	ATGGTGTTGGGGGAGGGGGTTCCTTCT	0	CCCCTCTGAGTCAGGAAACATTTTCAG	0	-	ILLUMINA	NA	182	TRUE	
ERBB2_1	ERBB2_1.chr17.37880219.37880261	ERBB2_1.chr17.37880219.37880261_tile_1	Homo sapiens	hg19	chr17	37880219	37880261	-	CATATCTCCCCAAACCCCAATGAAGAG	0	CTTTGATGGCCACTGGAATTTTCACA	0	-	ILLUMINA	NA	172	TRUE	
ERBB2_4	ERBB2_4.chr17.37880993.37881012	ERBB2_4.chr17.37880993.37881012_tile_1	Homo sapiens	hg19	chr17	37880993	37881012	-	ATACACCAGTTCAGCAGGTCCTGGGAG	0	TATGCTTCCTGGGGACAAGGGTAC	0	-	ILLUMINA	NA	190	TRUE	
ERBB2_13	ERBB2_13.chr17.37881332.37881440	ERBB2_13.chr17.37881332.37881440_tile_1	Homo sapiens	hg19	chr17	37881332	37881440	-	TCTGCTCCTTGGTCCTTCACCTAACCT	0	ACATCCTCCAGGTAGCTCATCCCCTGG	0	-	ILLUMINA	NA	186	TRUE	
SMAD4_1	SMAD4_1.chr18.48575169.48575170	SMAD4_1.chr18.48575169.48575170_tile_1	Homo sapiens	hg19	chr18	48575169	48575170	-	TACAAAAATTGAAACACTATTGAGATCCT	0	CGCATACTGACAATATTTAACATGTTTTAG	0	-	ILLUMINA	NA	172	TRUE	
SMAD4_2	SMAD4_2.chr18.48581198.48581198	SMAD4_2.chr18.48581198.48581198_tile_1	Homo sapiens	hg19	chr18	48581198	48581198	-	ATGTTGGGAAAGTTGGCAGTGCTGGTA	0	CAAAGTCATGCACATATTCATCCTTCAC	0	-	ILLUMINA	NA	180	TRUE	
SMAD4_3	SMAD4_3.chr18.48584560.48584560	SMAD4_3.chr18.48584560.48584560_tile_1	Homo sapiens	hg19	chr18	48584560	48584560	-	GCTGTCTAAAAATTAAGGCCCACATGG	0	TGATGCTATCTGCAACAGTCCTTCAC	0	-	ILLUMINA	NA	188	TRUE	
SMAD4_4	SMAD4_4.chr18.48586262.48586262	SMAD4_4.chr18.48586262.48586262_tile_1	Homo sapiens	hg19	chr18	48586262	48586262	-	ACTCATGTCATGATGAGTATTGTACTC	0	AATGCAAGCTCATTGTGAACAGGCCCT	0	-	ILLUMINA	NA	184	TRUE	
SMAD4_5	SMAD4_5.chr18.48591826.48591919	SMAD4_5.chr18.48591826.48591919_tile_1	Homo sapiens	hg19	chr18	48591826	48591919	-	CAATACCTTGCTCTCTCAATGGCTTCT	0	AGTAAGCAATGGAACACCAATACTCAG	0	-	ILLUMINA	NA	188	TRUE	
SMAD4_11	SMAD4_11.chr18.48593405.48593405	SMAD4_11.chr18.48593405.48593405_tile_1	Homo sapiens	hg19	chr18	48593405	48593405	-	GCACTTGGGTAGATCTTATGAACAGCA	0	TGCCTATGTGCAACCTTAGGAAGAAA	0	-	ILLUMINA	NA	172	TRUE	
SMAD4_12	SMAD4_12.chr18.48603032.48603094	SMAD4_12.chr18.48603032.48603094_tile_1	Homo sapiens	hg19	chr18	48603032	48603094	-	AAAGAATGAAAAGCATACTTACTGATAGC	0	CTGACGCAAATCAAAGACCTTTTAAGAA	0	-	ILLUMINA	NA	172	TRUE	
SMAD4_15	SMAD4_15.chr18.48604668.48604754	SMAD4_15.chr18.48604668.48604754_tile_1	Homo sapiens	hg19	chr18	48604668	48604754	-	GCATGGTATGAAGTACTTCGTCTAGGA	0	AAGGTCATCAACACCAATTCCAGCAG	0	-	ILLUMINA	NA	172	TRUE	
STK11_1	STK11_1.chr19.1207021.1207092	STK11_1.chr19.1207021.1207092_tile_1	Homo sapiens	hg19	chr19	1207021	1207092	-	CGCAACTTCTTCTTCTTGAGGATCTTG	0	TAGATGACCTCGGTGGAGTCGATGCGG	0	-	ILLUMINA	NA	178	TRUE	
STK11_4	STK11_4.chr19.1220487.1220502	STK11_4.chr19.1220487.1220502_tile_1	Homo sapiens	hg19	chr19	1220487	1220502	-	AAAGCCGGGGAGCCCTGGCTGGTC	0	AGATTTTGAGGGTGCCACCGGTGGTG	0	-	ILLUMINA	NA	181	TRUE	
STK11_8	STK11_8.chr19.1221264.1221319	STK11_8.chr19.1221264.1221319_tile_1	Homo sapiens	hg19	chr19	1221264	1221319	+	TGTACCCCTTCGAAGGGGACAACATCTA	0	GCTTTTGTGCAGAAATGTAGGGTTGG	0	+	ILLUMINA	NA	177	TRUE	
STK11_12	STK11_12.chr19.1223059.1223125	STK11_12.chr19.1223059.1223125_tile_1	Homo sapiens	hg19	chr19	1223059	1223125	-	ACATCCTGGCCGAGTCAGCAGAGCC	0	ACCGGTCCTTGGTGTCTGGGCTC	0	-	ILLUMINA	NA	188	TRUE	
JAK3_1	JAK3_1.chr19.17945696.17945696	JAK3_1.chr19.17945696.17945696_tile_1	Homo sapiens	hg19	chr19	17945696	17945696	-	ATCCCTGATCCCACTTTCATTCCCTCA	0	ATGCCCATCAGTGCCCTGGATCCTG	0	-	ILLUMINA	NA	176	TRUE	
JAK3_2	JAK3_2.chr19.17948009.17948009	JAK3_2.chr19.17948009.17948009_tile_1	Homo sapiens	hg19	chr19	17948009	17948009	-	TAGTGCTGTGTGCACTAATGGCAGACT	0	AGCTTGATGAGCCAAGTGTCGTAC	0	-	ILLUMINA	NA	190	TRUE	
SRC	SRC.chr20.36031762.36031762	SRC.chr20.36031762.36031762_tile_1	Homo sapiens	hg19	chr20	36031762	36031762	-	AAAGAGGAAGGGCCTCGCCCCTGGCAAT	0	TACTGGGGCTCGGTGGACGTGAAGTAG	0	-	ILLUMINA	NA	191	TRUE	
GNAS1	GNAS1.chr20.57484420.57484421	GNAS1.chr20.57484420.57484421_tile_1	Homo sapiens	hg19	chr20	57484420	57484421	-	ACAGCTGGTTATTCCAGAGGGACTGGG	0	GCGAAGCAGGTCCTGAAACAAAATTGA	0	-	ILLUMINA	NA	172	TRUE	
SMARCB1_1	SMARCB1_1.chr22.24133967.24133990	SMARCB1_1.chr22.24133967.24133990_tile_1	Homo sapiens	hg19	chr22	24133967	24133990	-	GCGAGTGGTTTTGAAACAGGTTTACA	0	ACATACGGAGGTAGTTTCCCACCTAT	0	-	ILLUMINA	NA	189	TRUE	
SMARCB1_3	SMARCB1_3.chr22.24143240.24143240	SMARCB1_3.chr22.24143240.24143240_tile_1	Homo sapiens	hg19	chr22	24143240	24143240	-	TTGTGGGGAGCACAAGGTCAAAGCAG	0	ATGCGGTTCCTGTTGATGGTTGTGGA	0	-	ILLUMINA	NA	175	TRUE	
SMARCB1_4	SMARCB1_4.chr22.24145582.24145582	SMARCB1_4.chr22.24145582.24145582_tile_1	Homo sapiens	hg19	chr22	24145582	24145582	-	ATGTCCTGCGTGTCAGGTCCAGAATCT	0	TTCTGCCCATCGATCTCCATGTCCAG	0	-	ILLUMINA	NA	176	TRUE	
SMARCB1_5_6	SMARCB1_5_6.chr22.24176352.24176357	SMARCB1_5_6.chr22.24176352.24176357_tile_1	Homo sapiens	hg19	chr22	24176352	24176357	-	ACTCCACCCCCACCCGATCCTCAGGA	0	TGTTGGCAAGACGCCTCATCCGCCTGG	0	-	ILLUMINA	NA	173	TRUE	
GNA11_4	GNA11_4.chr19.3114942.3115070	GNA11_4.chr19.3114942.3115070_tile_1	Homo sapiens	hg19	chr19	3114942	3115070	+	AGTGCGCGGTCCACCCCCTCCT	0	CTGCCCACCCAGCAGGACGTGCT	0	+	ILLUMINA	NA	182	TRUE	
GNA11_4	GNA11_4.chr19.3114942.3115070	GNA11_4.chr19.3114942.3115070_tile_2	Homo sapiens	hg19	chr19	3114942	3115070	-	CGGCACACCGGGCAAATGAGCC	0	TAGCCCAAGGTGGCGATGCGGTC	0	-	ILLUMINA	NA	177	TRUE	
GNA11_5	GNA11_5.chr19.3118922.3119051	GNA11_5.chr19.3118922.3119051_tile_1	Homo sapiens	hg19	chr19	3118922	3119051	+	TCCTGCTCCAGCCGATGTCAGTCT	0	GATCCACTGCTTTGAGAACGTGACAT	0	+	ILLUMINA	NA	189	TRUE	
GNA11_6	GNA11_6.chr19.3119204.3119357	GNA11_6.chr19.3119204.3119357_tile_2	Homo sapiens	hg19	chr19	3119204	3119357	+	GGATGGAGGAGAGCAAAGCCCTGTT	0	CATGGGGAGGGGCTCGCGGGCA	0	+	ILLUMINA	NA	189	TRUE	
GNA11_7	GNA11_7.chr19.3120987.3121177	GNA11_7.chr19.3120987.3121177_tile_1	Homo sapiens	hg19	chr19	3120987	3121177	-	AACATCTTCAGGATGAACTCCCGCGCC	0	ACGGCCCACCCAGCTCGACCCCC	0	-	ILLUMINA	NA	172	TRUE	
GNA11_7	GNA11_7.chr19.3120987.3121177	GNA11_7.chr19.3120987.3121177_tile_2	Homo sapiens	hg19	chr19	3120987	3121177	+	AGGTCCCCAGCGGGACGCCCAG	0	CAGCTCAACCTCAAGGAGTACAACCT	0	+	ILLUMINA	NA	187	TRUE	
GNA11_7	GNA11_7.chr19.3120987.3121177	GNA11_7.chr19.3120987.3121177_tile_3	Homo sapiens	hg19	chr19	3120987	3121177	-	AAAAATCTCCTCCCGCGGGCAGAG	0	AGGATGGTGTCCTTCACGGCCGC	0	-	ILLUMINA	NA	185	TRUE	
GNAQ_4	GNAQ_4.chr9.80412436.80412564	GNAQ_4.chr9.80412436.80412564_tile_1	Homo sapiens	hg19	chr9	80412436	80412564	-	CATTCTCATTGTGTCTTCCCTCCTCTA	0	GTAACTGAGTCCATGAAACCTATTTCC	0	-	ILLUMINA	NA	188	TRUE	
GNAQ_5	GNAQ_5.chr9.80409379.80409508	GNAQ_5.chr9.80409379.80409508_tile_1	Homo sapiens	hg19	chr9	80409379	80409508	-	GCTTAGTGAATATGATCAAGTTCTCGTGG	0	GCTTTCTTGAAATTTGATTTTAGGACTTTT	0	-	ILLUMINA	NA	174	TRUE	
GNAQ_5	GNAQ_5.chr9.80409379.80409508	GNAQ_5.chr9.80409379.80409508_tile_2	Homo sapiens	hg19	chr9	80409379	80409508	+	AGATAATAAAATGATAATCCATTGCCTGTC	0	TTGGCCCCCTACATCGACCATTCT	0	+	ILLUMINA	NA	177	TRUE	
GNAQ_5	GNAQ_5.chr9.80409379.80409508	GNAQ_5.chr9.80409379.80409508_tile_3	Homo sapiens	hg19	chr9	80409379	80409508	-	ATTGAATTGACTTGGATGATCATCGTC	0	GGTCAGAGAGAAGAAAATGGATACACT	0	-	ILLUMINA	NA	182	TRUE	
GNAQ_6	GNAQ_6.chr9.80343430.80343583	GNAQ_6.chr9.80343430.80343583_tile_1	Homo sapiens	hg19	chr9	80343430	80343583	-	GAAAATCATGTATTCCCATCTAGTCGACT	0	TTGCCCTGTGCAGCCTGCGTGTTGA	0	-	ILLUMINA	NA	172	TRUE	
GNAQ_6	GNAQ_6.chr9.80343430.80343583	GNAQ_6.chr9.80343430.80343583_tile_2	Homo sapiens	hg19	chr9	80343430	80343583	+	TTCACAGCTACTGAGCTGTGGTATGA	0	AGGGGTATGTGATAATTGTTCTAAAGAGAG	0	+	ILLUMINA	NA	171	TRUE	
GNAQ_6	GNAQ_6.chr9.80343430.80343583	GNAQ_6.chr9.80343430.80343583_tile_3	Homo sapiens	hg19	chr9	80343430	80343583	-	GGTCGTATACAAAAGATGGGTTGGACTTAT	0	GTTCCAGAACTCCTCGGTTATTCTGTT	0	-	ILLUMINA	NA	187	TRUE	
GNAQ_7	GNAQ_7.chr9.80336240.80336429	GNAQ_7.chr9.80336240.80336429_tile_1	Homo sapiens	hg19	chr9	80336240	80336429	-	ACCATCCTCCAGTTGAACCTGAAGG	0	TTTATTGCCGTCCTGGACTCTGTGTGAGCG	0	-	ILLUMINA	NA	172	TRUE	
GNAQ_7	GNAQ_7.chr9.80336240.80336429	GNAQ_7.chr9.80336240.80336429_tile_2	Homo sapiens	hg19	chr9	80336240	80336429	+	CAGGGAAGGGCAGGGCGGGTGTCTA	0	ATAATTTTGTCACTGTCTGGGTTCAGG	0	+	ILLUMINA	NA	172	TRUE	
GNAQ_7	GNAQ_7.chr9.80336240.80336429	GNAQ_7.chr9.80336240.80336429_tile_3	Homo sapiens	hg19	chr9	80336240	80336429	-	CCAATGATGATTGAATACATTAGCAGAT	0	TACTCCCACTTCACGTGCGCCACAGAC	0	-	ILLUMINA	NA	177	TRUE	
[Targets]																		
TargetA	TargetB	Target Number	Chromosome	Start Position	End Position	Probe Strand	Sequence	Species	Build ID									
MPL1_2.chr1.43815008.43815009_tile_1	MPL1_2.chr1.43815008.43815009_tile_1	1	chr1	43814982	43815163	+	GGTGGCAGTTTCCTGCACACTACAGGTACCGCCCCCGCCAGGCAGGAGACTGGCGGTGGACCAGGTGGAGCCGAAGGCCTGTAAACAGGCATTCTTGGTTCGCTCTGTGACCCCAGATCTCCGTCCACCGCC	Homo sapiens	hg19									
NRAS1_7.chr1.115256528.115256531_tile_1	NRAS1_7.chr1.115256528.115256531_tile_1	1	chr1	115256500	115256680	+	TCTTGTCCAGCTGTATCCAGTATGTCCAACAAACAGGTTTCACCATCTATAACCACTTGTTTTCTGTAAGAATCCTGGGGGTGTGGAGGGTAAGGGGGCAGGGAGGGAGGGAAGTTCAATTTTTATTA	Homo sapiens	hg19									
NRAS8_13.chr1.115258730.115258748_tile_1	NRAS8_13.chr1.115258730.115258748_tile_1	1	chr1	115258702	115258884	+	TGCGCTTTTCCCAACACCACCTGCTCCAACCACCACCAGTTTGTACTCAGTCATTTCACACCAGCAAGAACCTGTTGGAAACCAGTAATCAGGGTTAATTGGCGAGCCACATCTACAGTACTTTAAAG	Homo sapiens	hg19									
ALK1.chr2.29432664.29432664_tile_1	ALK1.chr2.29432664.29432664_tile_1	1	chr2	29432636	29432822	+	TCGGGCCATCCCGAAGTCTCCAATCTTGGCCACTCTTCCAGGGCCTGGACAGGTCAAGAGGCAGTTTCTGGCAGCAATGTCTCTGGGAAGAAAGGAAATGCATTTCCTAATTTTATCCCTAGGAAGATGAGTG	Homo sapiens	hg19									
ALK2.chr2.29443695.29443695_tile_1	ALK2.chr2.29443695.29443695_tile_1	1	chr2	29443667	29443836	+	GTTGAATTTGCTGCAGAGCAGAGAGGGATGTAACCAAAATTAACTGAGCTGAGTCTGGGCAAATCTTAAACTGGGAGGAACAGGATACAAAGTTACATTTTCAGCAGCTACAATGTATA	Homo sapiens	hg19									
IDH1_1_2.chr2.209113112.209113113_tile_1	IDH1_1_2.chr2.209113112.209113113_tile_1	1	chr2	209113084	209113264	+	ACGACCTATGATGATAGGTTTTACCCATCCACTCACAAGCCGGGGGATATTTTTGCAGATAATGGCTTCTCTGAAGACCGTGCCACCCAGAATATTTCGTATGGTGCCATTTGGTGATTTCCACATT	Homo sapiens	hg19									
ERBB4_1_2.chr2.212288942.212288955_tile_1	ERBB4_1_2.chr2.212288942.212288955_tile_1	1	chr2	212288912	212289100	+	CCTTTCTCTAATAAATCAGGGATTTCTCGCGTTGGAATTCCATCATAGGGTTTTCCTCCAAAGGTCATCAGTTCCCATATAGTAACTCCTATATTGGAGAAAAAATTCTTACTTAAGCATATTAACAACATATGT	Homo sapiens	hg19									
ERBB4_3_4.chr2.212530066.212530135_tile_1	ERBB4_3_4.chr2.212530066.212530135_tile_1	1	chr2	212530036	212530210	+	TGGATGGCATGGGTGGCACTCCCGATCTGGATCAGCATACTTGAAAATGAAACTGTTTGCCCCCTGTAAGCCATCTGGACATTTTTCCACACAGTTTGGGCCATCTTTAAAATGAGAGCACT	Homo sapiens	hg19									
ERBB4_5.chr2.212576857.212576857_tile_1	ERBB4_5.chr2.212576857.212576857_tile_1	1	chr2	212576821	212576990	+	AATCCACAGTCTGAGCTGACATCAATGATCCTGTGCCAATGCCATCACAAGCTGTAGAAACAAGACTCAGAGTTAGGGGATTGAGAAACTTATTTTTGGCCAATAAATCA	Homo sapiens	hg19									
ERBB4_6_7.chr2.212578341.212578349_tile_1	ERBB4_6_7.chr2.212578341.212578349_tile_1	1	chr2	212578315	212578499	+	CGCACACAAGAACTGGAATCTACCACAAAGTTATCTGATTAAAAAAAAAAAAAAGGTAAAATAAGCATTAATGTTAACATTCAGCAAACAAGCTCAAAACAAGATATTTTAGGGTTTAAAAATGATTAGCA	Homo sapiens	hg19									
ERBB4_8.chr2.212587147.212587147_tile_1	ERBB4_8.chr2.212587147.212587147_tile_1	1	chr2	212587115	212587285	+	CTCCATATGTGTACTTTGCATTGAAATTGTGCTCCAGTTGAAAGGTGGTTGGATTGTAGACAAAGGTTTGGGGACACTGAGTAACACATGCTCCACTGTCATTGAAATTCATGCAGG	Homo sapiens	hg19									
ERBB4_9.chr2.212589811.212589811_tile_1	ERBB4_9.chr2.212589811.212589811_tile_1	1	chr2	212589783	212589957	+	TGTGTCCTTAGGTCCTGAGCAGCCTCCAGCACATTCTCGATGGCAGCAGTCACTGACGTAAGGTCCGTAGCATCTGCCGTCACATTGTTCTGCACACACCGTCCTTGTCACTGCAGAAGAC	Homo sapiens	hg19									
ERBB4_10.chr2.212652764.212652764_tile_1	ERBB4_10.chr2.212652764.212652764_tile_1	1	chr2	212652706	212652876	+	ATAATTCTACTTACATCCTGAACTACCATTTGTTGACACAAGAGTCAAGTTGGAAGGCCATGGGTTCCGAACAATATCTTGCCAATGAATGGTGTCTGCATAACAAAGGAATTT	Homo sapiens	hg19									
ERBB4_11.chr2.212812157.212812157_tile_1	ERBB4_11.chr2.212812157.212812157_tile_1	1	chr2	212812127	212812311	+	TGTCAAGTTCTTTAATCCAAGTTCTTGAAGTCCAAAGTTTCCATCTTTTCTGTAGTTTAAAAATATTGCCAAGGCATATCGATCCTCATAAAGTTTTGTCCCACGAATAATGCGTAAATTCTCCAGAGG	Homo sapiens	hg19									
VHL1_2.chr3.10183797.10183817_tile_1	VHL1_2.chr3.10183797.10183817_tile_1	1	chr3	10183769	10183952	+	GGCTCAACTTCGACGGCGAGCCGCAGCCCTACCCAACGCTGCCGCCTGGCACGGGCCGCCGCATCCACAGCTACCGAGGTACGGGCCCGGCGCTTAGGCCCGACCCAGCAGGGACGATAGCACGGTCTGAAGC	Homo sapiens	hg19									
VHL3_5.chr3.10188245.10188301_tile_1	VHL3_5.chr3.10188245.10188301_tile_1	1	chr3	10188217	10188401	+	GGTTAACCAAACTGAATTATTTGTGCCATCTCTCAATGTTGACGGACAGCCTATTTTTGCCAATATCACACTGCCAGGTACTGACGTTTTACTTTTTAAAAAGATAAGGTTGTTGTGGTAAGTACAGGATA	Homo sapiens	hg19									
VHL6_8.chr3.10191480.10191506_tile_1	VHL6_8.chr3.10191480.10191506_tile_1	1	chr3	10191450	10191634	+	TCTGAAAGAGCGATGCCTCCAGGTTGTCCGGAGCCTAGTCAAGCCTGAGAATTACAGGAGACTGGACATCGTCAGGTCGCTCTACGAAGATCTGGAAGACCACCCAAATGTGCAGAAAGACCTGGAGCGG	Homo sapiens	hg19									
MLH1.chr3.37067240.37067240_tile_1	MLH1.chr3.37067240.37067240_tile_1	1	chr3	37067212	37067394	+	GGTTCGTACAGATTCCCGGGAACAGAAGCTTGATGCATTTCTGCAGCCTCTGAGCAAACCCCTGTCCAGTCAGCCCCAGGCCATTGTCACAGAGGATAAGACAGATATTTCTAGTGGCAGGGCTAGGCAG	Homo sapiens	hg19									
CTNNB1_1_16.chr3.41266040.41266137_tile_1	CTNNB1_1_16.chr3.41266040.41266137_tile_1	1	chr3	41266010	41266180	+	ATGGCCATGGAACCAGACAGAAAAGCGGCTGTTAGTCACTGGCAGCAACAGTCTTACCTGGACTCTGGAATCCATTCTGGTGCCACTACCACAGCTCCTTCTCTGAGTGGTAAAGGC	Homo sapiens	hg19									
PIK3CA1.chr3.178916876.178916876_tile_1	PIK3CA1.chr3.178916876.178916876_tile_1	1	chr3	178916836	178917024	+	TGATGAAACAAGACGACTTTGTGACCTTCGGCTTTTTCAACCCTTTTTAAAAGTAATTGAACCAGTAGGCAACCGTGAAGAAAAGATCCTCAATCGAGAAATTGGTATGATACAATATCCTATTCTAAAATGCAAA	Homo sapiens	hg19									
PIK3CA2.chr3.178921553.178921553_tile_1	PIK3CA2.chr3.178921553.178921553_tile_1	1	chr3	178921525	178921709	+	ATGTAAATATTCGAGACATTGATAAGGTAAAGTCAAATGCTGATGCTTATTATTTTATAGAAATTATTTTAGATAACCTTTTTCTTGCACTATACAGTAATCTGTTGACCTGTAGTATGTTTTCAGATGGT	Homo sapiens	hg19									
PIK3CA3.chr3.178927980.178927980_tile_1	PIK3CA3.chr3.178927980.178927980_tile_1	1	chr3	178927906	178928082	+	TTATAATTTAGACTAGTGAATATTTTTCTTTGTTTTTTAAGGAACACTGTCCATTGGCATGGGGAAATATAAACTTGTTTGATTACACAGACACTCTAGTATCTGGAAAAATGGCTTTGAATC	Homo sapiens	hg19									
PIK3CA4_11.chr3.178936074.178936095_tile_1	PIK3CA4_11.chr3.178936074.178936095_tile_1	1	chr3	178936044	178936214	+	ATCCTCTCTCTGAAATCACTGAGCAGGAGAAAGATTTTCTATGGAGTCACAGGTAAGTGCTAAAATGGAGATTCTCTGTTTCTTTTTCTTTATTACAGAAAAAATAACTGAATTTGG	Homo sapiens	hg19									
PIK3CA12.chr3.178938860.178938860_tile_1	PIK3CA12.chr3.178938860.178938860_tile_1	1	chr3	178938832	178939004	+	CACCTGAATAGGCAAGTCGAGGCAATGGAAAAGCTCATTAACTTAACTGACATTCTCAAACAGGAGAAGAAGGATGAAACACAAAAGGTGTGTGACTCTAGTTTGTGTTTGAGACTCTT	Homo sapiens	hg19									
PIK3CA13_20.chr3.178952007.178952150_tile_1	PIK3CA13_20.chr3.178952007.178952150_tile_1	1	chr3	178951881	178952054	+	TATCTAGCTATTCGACAGCATGCCAATCTCTTCATAAATCTTTTCTCAATGATGCTTGGCTCTGGAATGCCAGAACTACAATCTTTTGATGACATTGCATACATTCGAAAGACCCTAGCC	Homo sapiens	hg19									
PIK3CA13_20.chr3.178952007.178952150_tile_2	PIK3CA13_20.chr3.178952007.178952150_tile_2	1	chr3	178951999	178952184	-	TTTCAGTTCAATGCATGCTGTTTAATTGTGTGGAAGATCCAATCCATTTTTGTTGTCCAGCCACCATGATGTGCATCATTCATTTGTTTCATGAAATACTCCAAAGCCTCTTGCTCAGTTTTATCTAAG	Homo sapiens	hg19									
FGFR3_1_2.chr4.1803564.1803568_tile_1	FGFR3_1_2.chr4.1803564.1803568_tile_1	1	chr4	1803538	1803712	+	GCGCTCCCCGCACCGGCCCATCCTGCAGGCGGGGCTGCCGGCCAACCAGACGGCGGTGCTGGGCAGCGACGTGGAGTTCCACTGCAAGGTGTACAGTGACGCACAGCCCCACATCCAGTGGCT	Homo sapiens	hg19									
FGFR3_3_4.chr4.1806119.1806153_tile_1	FGFR3_3_4.chr4.1806119.1806153_tile_1	1	chr4	1806091	1806277	+	CGGGGTGGGCTTCTTCCTGTTCATCCTGGTGGTGGCGGCTGTGACGCTCTGCCGCCTGCGCAGCCCCCCCAAGAAAGGCCTGGGCTCCCCCACCGTGCACAAGATCTCCCGCTTCCCGCTCAAGCGACAGGTA	Homo sapiens	hg19									
FGFR3_5_7.chr4.1807862.1807890_tile_1	FGFR3_5_7.chr4.1807862.1807890_tile_1	1	chr4	1807836	1808025	+	CCGGGACGTGCACAACCTCGACTACTACAAGAAGACGACCAACGTGAGCCCGGCCCTGGGGTGCGGGGGTGGGGGTCATGCCAGTAGGACGCCTGGCGCCAACACCGCCTTCCCACACCCTCCCAGGGCCGGCTGCCCGTGA	Homo sapiens	hg19									
FGFR3_8.chr4.1808331.1808331_tile_1	FGFR3_8.chr4.1808331.1808331_tile_1	1	chr4	1808295	1808464	+	GCTCCCCGTACCCCGGCATCCCTGTGGAGGAGCTCTTCAAGCTGCTGAAGGAGGGCCACCGCATGGACAAGCCCGCCAACTGCACACACGACCTGTGAGTGGCATCCCTGGCCCTCCACTGGGTCC	Homo sapiens	hg19									
FGFR3_9.chr4.1808949.1808949_tile_1	FGFR3_9.chr4.1808949.1808949_tile_1	1	chr4	1808921	1809105	+	CCTGCTGCCCCCGGCCCCACCCAGCAGTGGGGGCTCGCGGACGTGAAGGGCCACTGGTCCCCAACAATGTGAGGGGTCCCTAGCAGCCCACCCTGCTGCTGGTGCACAGCCACTCCCCGGCATGAGACTCAGTGC	Homo sapiens	hg19									
PDGFRA1_4.chr4.55141013.55141049_tile_1	PDGFRA1_4.chr4.55141013.55141049_tile_1	1	chr4	55140981	55141157	+	AAACCGAGGTATGAAATTCGCTGGAGGGTCATTGAATCAATCAGCCCAGATGGACATGAATATATTTATGTGGACCCGATGCAGCTGCCTTATGACTCAAGATGGGAGTTTCCAAGAGATGGA	Homo sapiens	hg19									
PDGFRA5.chr4.55144146.55144146_tile_1	PDGFRA5.chr4.55144146.55144146_tile_1	1	chr4	55144120	55144306	+	AACTTGCTGGGAGCCTGCACCAAGTCAGGTGGGCTCACTGACCTGGAGTGAGGATTTTCACTGGACACATGTGGTTGTGAAAACTGTTCAATCAGGCTTAAATCCTCCACTCTCCATCCCCACACATGGCAGGG	Homo sapiens	hg19									
PDGFRA6.chr4.55144547.55144547_tile_1	PDGFRA6.chr4.55144547.55144547_tile_1	1	chr4	55144519	55144703	+	CACAGAGTATTGCTTCTATGGAGATTTGGTCAACTATTTGCATAAGAATAGGGATAGCTTCCTGAGCCACCACCCAGAGAAGCCAAAGAAAGAGCTGGATATCTTTGGATTGAACCCTGCTGATGAAAGCAC	Homo sapiens	hg19									
PDGFRA7_23.chr4.55152040.55152109_tile_1	PDGFRA7_23.chr4.55152040.55152109_tile_1	1	chr4	55152012	55152184	+	CGTCCTCCTGGCACAAGGAAAAATTGTGAAGATCTGTGACTTTGGCCTGGCCAGAGACATCATGCATGATTCGAACTATGTGTCGAAAGGCAGTGTACGTCCTCACTTCCCTCACTGGTCA	Homo sapiens	hg19									
KIT1.chr4.55561764.55561764_tile_1	KIT1.chr4.55561764.55561764_tile_1	1	chr4	55561736	55561913	+	CGACGAGATTAGGCTGTTATGCACTGATCCGGGCTTTGTCAAATGGACTTTTGAGATCCTGGATGAAACGAATGAGAATAAGCAGAATGAATGGATCACGGAAAAGGCAGAAGCCACCAACACCG	Homo sapiens	hg19									
KIT2.chr4.55592185.55592186_tile_1	KIT2.chr4.55592185.55592186_tile_1	1	chr4	55592155	55592341	+	CCTATTTTAACTTTGCATTTAAAGGTAACAACAAAGGTATATTTCTTTTTAATCCAATTTAAGGGGATGTTTAGGCTCTGTCTACCATATCAGTCATGATTTTAAGTTCATTCCAACATTGACCATGTCATTTC	Homo sapiens	hg19									
KIT3_19.chr4.55593464.55593689_tile_1	KIT3_19.chr4.55593464.55593689_tile_1	1	chr4	55593342	55593512	+	ATTTCTCTTCCATTGTAGAGCAAATCCATCCCCACACCCTGTTCACTCCTTTGCTGATTGGTTTCGTAATCGTAGCTGGCATGATGTGCATTATTGTGATGATTCTGACCTACAAATA	Homo sapiens	hg19									
KIT3_19.chr4.55593464.55593689_tile_2	KIT3_19.chr4.55593464.55593689_tile_2	1	chr4	55593436	55593609	-	TTCTGTGGGGAGAAAGGGAAAAATAGATCACCTTTTAATAATTATTGTCTCAGTCATTAGAGCACTCTGGAGAGAGAACAAATAAATGGTTACCTGTAAATATTTGTAGGTCAGAATCATCA	Homo sapiens	hg19									
KIT3_19.chr4.55593464.55593689_tile_3	KIT3_19.chr4.55593464.55593689_tile_3	1	chr4	55593556	55593739	+	AACCCATGTATGAAGTACAGTGGAAGGTTGTTGAGGAGATAAATGGAAACAATTATGTTTACATAGACCCAACACAACTTCCTTATGATCACAAATGGGAGTTTCCCAGAAACAGGCTGAGTTTTGGTCAG	Homo sapiens	hg19									
KIT20_21.chr4.55594221.55594258_tile_1	KIT20_21.chr4.55594221.55594258_tile_1	1	chr4	55594193	55594380	+	CAAAGTCCTGAGTTACCTTGGTAATCACATGAATATTGTGAATCTACTTGGAGCCTGCACCATTGGAGGTAAAGCCGTGTCCAAGCTGCCTTTTATTGTCTGTCAGGTTATCAAAACATGACATTTTAATATG	Homo sapiens	hg19									
KIT22.chr4.55595519.55595519_tile_1	KIT22.chr4.55595519.55595519_tile_1	1	chr4	55595493	55595675	+	CAGAATATTGTTGCTATGGTGATCTTTTGAATTTTTTGAGAAGAAAACGTGATTCATTTATTTGTTCAAAGCAGGAAGATCATGCAGAAGCTGCACTTTATAAGAATCTTCTGCATTCAAAGGAGTCT	Homo sapiens	hg19									
KIT23.chr4.55597495.55597497_tile_1	KIT23.chr4.55597495.55597497_tile_1	1	chr4	55597467	55597652	+	CAGCGATAGTACTAATGAGTACATGGACATGAAACCTGGAGTTTCTTATGTTGTCCCAACCAAGGCCGACAAAAGGAGATCTGTGAGAATAGGTGAGTACCTACCTATCAAGCAACCAAGAGTAACTTTAC	Homo sapiens	hg19									
KIT24_28.chr4.55599320.55599348_tile_1	KIT24_28.chr4.55599320.55599348_tile_1	1	chr4	55599290	55599472	+	AGAGACATCAAGAATGATTCTAATTATGTGGTTAAAGGAAACGTGAGTACCCATTCTCTGCTTGACAGTCCTGCAAAGGATTTTTAGTTTCAACTTTCGATAAAAATTGTTTCCTGTGATTTTCATAAT	Homo sapiens	hg19									
KIT29.chr4.55602694.55602694_tile_1	KIT29.chr4.55602694.55602694_tile_1	1	chr4	55602666	55602850	+	CCTGAAAGCATTTTCAACTGTGTATACACGTTTGAAAGTGACGTCTGGTCCTATGGGATTTTTCTTTGGGAGCTGTTCTCTTTAGGTAAAATGATCCTTGCCAAAGACAACTTCATTAGACTCAGAGCATCTT	Homo sapiens	hg19									
KDR1.chr4.55946114.55946257_tile_1	KDR1.chr4.55946114.55946257_tile_1	1	chr4	55945984	55946155	+	CGGCTACTTCCTGCTGGTGGAAAGAACAACACTTGAAAATCTGAGCAGCACCTCTCATGTGATGTCCAGGAGTTGGGGGTGTGGATGCTTCCTTTTAAACAGGAGGAGAGCT	Homo sapiens	hg19									
KDR1.chr4.55946114.55946257_tile_2	KDR1.chr4.55946114.55946257_tile_2	1	chr4	55946098	55946284	-	GGATATCACTCCGATGACACAGACACCACCGTGTACTCCAGTGAGGAAGCAGAACTTTTAAAGCTGATAGAGATTGGAGTGCAAACCGGTAGCACAGCCCAGATTCTCCAGCCTGACTCGGGGACCACACTGA	Homo sapiens	hg19									
KDR3.chr4.55953807.55953807_tile_1	KDR3.chr4.55953807.55953807_tile_1	1	chr4	55953777	55953965	+	TTGGGGTCACATACTTCCTCCTCCTCCATACAGGAAACAGGTGAGGTAGGCAGAGAGAGTCCAGAATCCTCTTCCATGCTCAAAGTCTCTGATATCGGAAGAACAATGTAGTCTTTGCCATCCTGAAACAATAAA	Homo sapiens	hg19									
KDR4.chr4.55955111.55955127_tile_1	KDR4.chr4.55955111.55955127_tile_1	1	chr4	55955085	55955257	+	CCCCGTGCCAGCAGTCCAGCATGGTCTGGTACCTAGAGAAGCAAAACACTGATTTCATTAAATGCCTCTTTCTTCCTGAATGCTGAAAATAAGCACTTAAATGAGTACACATTTGTAAAGAG	Homo sapiens	hg19									
KDR6.chr4.55960989.55961023_tile_1	KDR6.chr4.55960989.55961023_tile_1	1	chr4	55960959	55961129	+	TCACTGAGGGACTTCTCCTCCACAAATCCAGAGCTGGCTGAGCTCTGGCTACTGGTGATGCTGTCCAAGCGCCGTTTCAGATCCACAGGGATTGCTCCAACGTAGTCTTTCCCTTGA	Homo sapiens	hg19									
KDR8.chr4.55962507.55962507_tile_1	KDR8.chr4.55962507.55962507_tile_1	1	chr4	55962477	55962653	+	GCTCCTTCTACAAATACAGTACAAAGAGGGAAATCATAGGTATGGACATTTCCTTCAATAATTGGGGTCCCTCCCTCCCTGCATGCCACTATACAACTTACCCTCCGGGGTAACACAGCTGTGA	Homo sapiens	hg19									
KDR9.chr4.55972964.55972964_tile_1	KDR9.chr4.55972964.55972964_tile_1	1	chr4	55972936	55973106	+	ACTGAGACAGCTTGGCTATAAGAAAGAGATAACAGCGCATATTATGATTTAATTTTTCTTTAATTAGAGTCAAGAGTAAGGAAAAGATTCAGACTTTGGTTATTCTGTTCTTAGAAA	Homo sapiens	hg19									
KDR10.chr4.55979623.55979623_tile_1	KDR10.chr4.55979623.55979623_tile_1	1	chr4	55979595	55979775	+	CTCGGTTTACAAGTTTCTTATGCTGATGCTGAAAAAAAGAGTTGACTGAACTTCCAAAGCACAGCATATAACATTACCCAATAACTTCTAGTAACACACAGAATTAAATCTGGGCTTTGGTAAACATT	Homo sapiens	hg19									
KDR11.chr4.55980348.55980348_tile_1	KDR11.chr4.55980348.55980348_tile_1	1	chr4	55980320	55980496	+	TGCTGTACAATTTAAGACAAGCTTTTCTCCAACAGATAGTTCAATTCCATGAGACGGACTCAGAACCACATCATAAATCCTATACCCTAGAGCAAGTAAATTGAAAAAACAGAACATGAGAGA	Homo sapiens	hg19									
FBXW7_1.chr4.153245446.153245446_tile_1	FBXW7_1.chr4.153245446.153245446_tile_1	1	chr4	153245416	153245604	+	AACGACTGGTGCCCTGTTAACGTGTGAATGCAATTCCCTGTCTCCACATCCCAAACACGGATTGATGTATCAAGAGATCCACTCACCACATGGATACCATCAAACTACAAAAGACACAGTTTATTAGAATAGA	Homo sapiens	hg19									
FBXW7_2.chr4.153247288.153247366_tile_1	FBXW7_2.chr4.153247288.153247366_tile_1	1	chr4	153247248	153247417	+	TTGAACACAGCGGACTGCTGCAACATGACCCATCAAAACATGTAAACACTGGCCTGTCTCAATATCCCAAACCCTAAGAGTGGCATCTCGAGAACCGCTAACAACTCTGCAG	Homo sapiens	hg19									
FBXW7_5.chr4.153249384.153249384_tile_1	FBXW7_5.chr4.153249384.153249384_tile_1	1	chr4	153249338	153249520	+	TTCATGAAGATGCATACAACGCACAGTGGAAGTATGCCCATATAAGGTGTGTATACATTCTCCAGTCTCTGCATTCCACACTTTGAGTGTCCGATCTGTAGATCCACTAATGATGATGTTGTCTCTCAT	Homo sapiens	hg19									
FBXW7_7.chr4.153250883.153250883_tile_1	FBXW7_7.chr4.153250883.153250883_tile_1	1	chr4	153250853	153251031	+	ATTCGGTTACCACAAAACTGTAAGCATGTGATCACATGATCATCATGTCCTTTCAGCACCTATAAGAAAGATGTGCAGATTAGAAATATGTTAATTAAATTATGTTCTTTAAAATACTGGTGAAGA	Homo sapiens	hg19									
FBXW7_8.chr4.153258983.153258983_tile_1	FBXW7_8.chr4.153258983.153258983_tile_1	1	chr4	153258953	153259142	+	TCGTTGAAACTGGGGTTCTATCACTTGCATCATATGTTTTACTTGTGTTGGTTCACAACTATCAATGAGTTCATCTAAAGCAAGCAATTTCTCTGGTCCACTCCAGCTCTATCAAAGAGAATTAGAAATTTT	Homo sapiens	hg19									
APC1.chr5.112173917.112173917_tile_1	APC1.chr5.112173917.112173917_tile_1	1	chr5	112173887	112174071	+	AAGCGAGGTTTGCAGATCTCCACCACTGCAGCCCAGATTGCCAAAGTCATGGAAGAAGTGTCAGCCATTCATACCTCTCAGGAAGACAGAAGTTCTGGGTCTACCACTGAATTACATTGTGTGACAGATGA	Homo sapiens	hg19									
APC2.chr5.112174631.112174631_tile_1	APC2.chr5.112174631.112174631_tile_1	1	chr5	112174603	112174775	+	TCGAGTGGGTTCTAATCATGGAATTAATCAAAATGTAAGCCAGTCTTTGTGTCAAGAAGATGACTATGAAGATGATAAGCCTACCAATTATAGTGAACGTTACTCTGAAGAAGAACAGC	Homo sapiens	hg19									
APC3_42.chr5.112175162.112175958_tile_1	APC3_42.chr5.112175162.112175958_tile_1	1	chr5	112175034	112175208	-	TCTGCTTCCTGTGTCGTCTGATTACATCCTATTTCATCTTCAGCTGATGACAAAGATGATAATGAACTACATCTTGAAAAACATATTGGAGTATCTTCTACACAATAAGTCTGTATTGTT	Homo sapiens	hg19									
APC3_42.chr5.112175162.112175958_tile_2	APC3_42.chr5.112175162.112175958_tile_2	1	chr5	112175128	112175297	+	ATGTAATCAGACGACACAGGAAGCAGATTCTGCTAATACCCTGCAAATAGCAGAAATAAAAGAAAAGATTGGAACTAGGTCAGCTGAAGATCCTGTGAGCGAAGTTCCAGCAGTGTCAC	Homo sapiens	hg19									
APC3_42.chr5.112175162.112175958_tile_3	APC3_42.chr5.112175162.112175958_tile_3	1	chr5	112175216	112175386	-	CCTGAAGAAAATTCAACAGCTTTGTGCCTGGCTGATTCTGAAGATAAACTAGAACCCTGCAGTCTGCTGGATTTGGTTCTAGGGTGCTGTGACACTGCTGGAACTTCGCTCACAGGAT	Homo sapiens	hg19									
APC3_42.chr5.112175162.112175958_tile_4	APC3_42.chr5.112175162.112175958_tile_4	1	chr5	112175306	112175475	+	CACAAAGCTGTTGAATTTTCTTCAGGAGCGAAATCTCCCTCCAAAAGTGGTGCTCAGACACCCAAAAGTCCACCTGAACACTATGTTCAGGAGACCCCACTCATGTTTAGCA	Homo sapiens	hg19									
APC3_42.chr5.112175162.112175958_tile_5	APC3_42.chr5.112175162.112175958_tile_5	1	chr5	112175394	112175566	-	GCCACTTACCATTCCACTGCATGGTTCACTCTGAACGGAGCTGGCAATCGAACGACTCTCAAAACTATCAAGTGAACTGACAGAAGTACATCTGCTAAACATGAGTGGGGTCTCCTGAAC	Homo sapiens	hg19									
APC3_42.chr5.112175162.112175958_tile_6	APC3_42.chr5.112175162.112175958_tile_6	1	chr5	112175512	112175683	+	GCATTATAAGCCCCAGTGATCTTCCAGATAGCCCTGGACAAACCATGCCACCAAGCAGAAGTAAAACACCTCCACCACCTCCTCAAACAGCTCAAACCAAGCGAGAAGTACCTAAAAATA	Homo sapiens	hg19									
APC3_42.chr5.112175162.112175958_tile_7	APC3_42.chr5.112175162.112175958_tile_7	1	chr5	112175630	112175799	-	CCGTGGCAAAATGTAATAAAGTATCAGCATCTGGAAGAACCTGGACCCTCTGAACTGCAGCATTTACTGCAGCTTGCTTAGGTCCACTCTCTCTCTTTTCAGCAGTAGGTGCTTT	Homo sapiens	hg19									
APC3_42.chr5.112175162.112175958_tile_8	APC3_42.chr5.112175162.112175958_tile_8	1	chr5	112175740	112175911	+	GGAAAGTACTCCAGATGGATTTTCTTGTTCATCCAGCCTGAGTGCTCTGAGCCTCGATGAGCCATTTATACAGAAAGATGTGGAATTAAGAATAATGCCTCCAGTTCAGGAA	Homo sapiens	hg19									
APC3_42.chr5.112175162.112175958_tile_9	APC3_42.chr5.112175162.112175958_tile_9	1	chr5	112175854	112176042	-	AGTATTTCAATATCATCATCATCTGAATCATCTAATAGGTCCTTTTCAGAATCAATAGTTTTTTCTGCCTCTTTCTCTTGGTTTTCATTTGATTCTTTAGGCTGCTCTGATTCTGTTTCATTCCCATTGTCATTT	Homo sapiens	hg19									
CSF1R1_3.chr5.149433644.149433646_tile_1	CSF1R1_3.chr5.149433644.149433646_tile_1	1	chr5	149433616	149433799	+	GATAGTTGTTGGGCTGCAGCAAGGGCTGGGCGATATCCCCTTGCTCGCAGCAGGTCAGGTGCTCACTAGAGCTCTCCTCCTCCAGCTCACTGCTGCTGCTGCCGCTGCCACCGCTTCTGCTGCTGCTCGGC	Homo sapiens	hg19									
CSF1R4.chr5.149453044.149453044_tile_1	CSF1R4.chr5.149453044.149453044_tile_1	1	chr5	149453016	149453189	+	CAAGTAGGCACTCTCTGGAAAGCAGAACACACAAGCATCTGGCATTAGTGGGAAGATGTCCTTGTTTATTTGTCCATTTTGTCATCCACCCATTGATCCAGTCCCTGAGCAGCTATGTCAC	Homo sapiens	hg19									
NPM1.chr5.170837547.170837548_tile_1	NPM1.chr5.170837547.170837548_tile_1	1	chr5	170837493	170837677	+	TTTTTTTTCCAGGCTATTCAAGATCTCTGGCAGTGGAGGAAGTCTCTTTAAGAAAATAGTTTAAACAATTTGTTAAAAAATTTTCCGTCTTATTTCATTTCTGTAACAGTTGATATCTGGCTGTCCTTTTTA	Homo sapiens	hg19									
EGFR1.chr7.55211080.55211080_tile_1	EGFR1.chr7.55211080.55211080_tile_1	1	chr7	55211052	55211238	+	AGAGGAAATATGTACTACGAAAATTCCTATGCCTTAGCAGTCTTATCTAACTATGATGCAAATAAAACCGGACTGAAGGAGCTGCCCATGAGAAATTTACAGGGTGAGAGGCTGGGATGCCAAGGCTGGGGGT	Homo sapiens	hg19									
EGFR2.chr7.55221822.55221822_tile_1	EGFR2.chr7.55221822.55221822_tile_1	1	chr7	55221792	55221964	+	GGTGCCACCTGCGTGAAGAAGTGTCCCCGTGAGTCCTCCTCTGTGGGCCCTCTAACTGGTCAGGCATCCTTGTCCCGCTCTGTCTCCTGCTGAGCCCTGGAGTATCCCATCTTGGAGAGT	Homo sapiens	hg19									
EGFR3.chr7.55233043.55233043_tile_1	EGFR3.chr7.55233043.55233043_tile_1	1	chr7	55233019	55233203	+	GGAGTCATGGGAGAAAACAACACCCTGGTCTGGAAGTACGCAGACGCCGGCCATGTGTGCCACCTGTGCCATCCAAACTGCACCTACGGGTGAGTGGAAAGTGAAGGAGAACAGAACATTTCCTCTCTTGCAAAT	Homo sapiens	hg19									
EGFR4.chr7.55241677.55241708_tile_1	EGFR4.chr7.55241677.55241708_tile_1	1	chr7	55241649	55241827	+	AGGAAACTGAATTCAAAAAGATCAAAGTGCTGGGCTCCGGTGCGTTCGGCACGGTGTATAAGGTAAGGTCCCTGGCACAGGCCTCTGGGCTGGGCCGCAGGGCCTCTCATGGTCTGGTGGGGAGCC	Homo sapiens	hg19									
EGFR9.chr7.55242418.55242511_tile_1	EGFR9.chr7.55242418.55242511_tile_1	1	chr7	55242388	55242576	+	GACTCTGGATCCCAGAAGGTGAGAAAGTTAAAATTCCCGTCGCTATCAAGGAATTAAGAGAAGCAACATCTCCGAAAGCCAACAAGGAAATCCTCGATGTGAGTTTCTGCTTTGCTGTGTGGGGGTCCATGGCT	Homo sapiens	hg19									
EGFR44.chr7.55249005.55249131_tile_1	EGFR44.chr7.55249005.55249131_tile_1	1	chr7	55248879	55249052	+	TCTTCACCTGGAAGGGGTCCATGTGCCCCTCCTTCTGGCCACCATGCGAAGCCACACTGACGTGCCTCTCCCTCCCTCCAGGAAGCCTACGTGATGGCCAGCGTGGACAACCCCCACGTGTG	Homo sapiens	hg19									
EGFR44.chr7.55249005.55249131_tile_2	EGFR44.chr7.55249005.55249131_tile_2	1	chr7	55249003	55249178	-	CAGTTGAGCAGGTACTGGGAGCCAATATTGTCTTTGTGTTCCCGGACATAGTCCAGGAGGCAGCCGAAGGGCATGAGCTGCGTGATGAGCTGCACGGTGGAGGTGAGGCAGATGCCCAGCAGGCGGC	Homo sapiens	hg19									
EGFR54.chr7.55259514.55259524_tile_1	EGFR54.chr7.55259514.55259524_tile_1	1	chr7	55259486	55259662	+	GCTGGCCAAACTGCTGGGTGCGGAAGAGAAAGAATACCATGCAGAAGGAGGCAAAGTAAGGAGGTGGCTTTAGGTCAGCCAGCATTTTCCTGACACCAGGGACCAGGCTGCCTTCCCACTAGC	Homo sapiens	hg19									
MET1.chr7.116339642.116339642_tile_1	MET1.chr7.116339642.116339642_tile_1	1	chr7	116339614	116339792	+	AGCCCAGCCAGTGTCCTGACTGTGTGGTGAGCGCCCTGGGAGCCAAAGTCCTTTCATCTGTAAAGGACCGGTTCATCAACTTCTTTGTAGGCAATACCATAAATTCTTCTTATTTCCCAGATCAT	Homo sapiens	hg19									
MET2.chr7.116340262.116340262_tile_1	MET2.chr7.116340262.116340262_tile_1	1	chr7	116340234	116340420	+	AACAAGATCGTCAACAAAAACAATGTGAGATGTCTCCAGCATTTTTACGGACCCAATCATGAGCACTGCTTTAATAGGGTAAGTCACATCAGTTCCCCACTTATAAACTGTGAGGTATAAATTAGAAATAAGT	Homo sapiens	hg19									
MET3.chr7.116411990.116411990_tile_1	MET3.chr7.116411990.116411990_tile_1	1	chr7	116411958	116412127	+	GCCCAACTACAGAAATGGTTTCAAATGAATCTGTAGACTACCGAGCTACTTTTCCAGAAGGTATATTTCAGTTTATTGTTCTGAGAAATACCTATACATATACCTCAGTGGGTTGT	Homo sapiens	hg19									
MET4.chr7.116417463.116417464_tile_1	MET4.chr7.116417463.116417464_tile_1	1	chr7	116417431	116417620	+	TATATCATGGGACTTTGTTGGACAATGATGGCAAGAAAATTCACTGTGCTGTGAAATCCTTGAACAGTAAGTGGCATTTTATTTAACCATGGAGTATACTTTTGTGGTTTGCAACCTAATAAATAGCTTATAATA	Homo sapiens	hg19									
MET6.chr7.116423413.116423474_tile_1	MET6.chr7.116423413.116423474_tile_1	1	chr7	116423385	116423555	+	TGTATGATAAAGAATACTATAGTGTACACAACAAAACAGGTGCAAAGCTGCCAGTGAAGTGGATGGCTTTGGAAAGTCTGCAAACTCAAAAGTTTACCACCAAGTCAGATGTGGTAAT	Homo sapiens	hg19									
SMO1.chr7.128845101.128845101_tile_1	SMO1.chr7.128845101.128845101_tile_1	1	chr7	128845073	128845257	+	GGTTCGGACAGACAACCCCAAGAGCTGGTACGAGGACGTGGAGGGCTGCGGCATCCAGTGCCAGAACCCGCTCTTCACAGAGGCTGAGCACCAGGACATGCACAGCTACATCGCGGCCTTCGGGGCCGTCACGGGC	Homo sapiens	hg19									
SMO2.chr7.128846040.128846040_tile_1	SMO2.chr7.128846040.128846040_tile_1	1	chr7	128846010	128846194	+	TACGCCCTGATGGCTGGTGTGGTTTGGTTTGTGGTCCTCACCTATGCCTGGCACACTTCCTTCAAAGCCCTGGGCACCACCTACCAGCCTCTCTCGGGCAAGACCTCCTACTTCCACCTGCTCACCTGGTC	Homo sapiens	hg19									
SMO3.chr7.128846374.128846374_tile_1	SMO3.chr7.128846374.128846374_tile_1	1	chr7	128846348	128846536	+	CGTGCTGGCCCCAATCGGCCTGGTGCTCATCGTGGGAGGCTACTTCCTCATCCGAGGTGAGTGAAGACCAGGCCAGGACCAGTTGGGCAACAAAATATACTGGGCACTTGCTGCCAGTACTGGGAGCTGCCAGCACG	Homo sapiens	hg19									
SMO4.chr7.128850341.128850341_tile_1	SMO4.chr7.128850341.128850341_tile_1	1	chr7	128850311	128850499	+	GCACCTGGGTCTGGACCAAGGCCACGCTGCTCATCTGGAGGCGTACCTGGTGCAGGTGGGCATGGCAGCCAGCCCCTCCTGCCCTGCCCGCCTCACCCTCAGCCTTGGGACCCCATCTTTAGGTTTTGTCGGGTCCTG	Homo sapiens	hg19									
SMO5.chr7.128851593.128851593_tile_1	SMO5.chr7.128851593.128851593_tile_1	1	chr7	128851563	128851734	+	GTCACCCCTGTGGCAACTCCAGGTATGAGAGTTCAAGCTTCTGGAGGAAGGTGGGGGGAGCACAGAGGCTGGGGGCTTCTGGGACTGGAGTACAGGGGCTGTCGGAGGAGGAGGAAGAG	Homo sapiens	hg19									
BRAF1.chr7.140453121.140453193_tile_1	BRAF1.chr7.140453121.140453193_tile_1	1	chr7	140453093	140453267	+	CACTCCATCGAGATTTCACTGTAGCTAGACCAAAATCACCTATTTTTACTGTGAGGTCTTCATGAAGAAATATATCTGAGGTGTAGTAAGTAAAGGAAAACAGTAGATCTCATTTTCCTATC	Homo sapiens	hg19									
BRAF28.chr7.140481397.140481478_tile_1	BRAF28.chr7.140481397.140481478_tile_1	1	chr7	140481369	140481545	+	ACTGTTCCAAATGATCCAGATCCAATTCTTTGTCCCACTGTAATCTGCCCATCAGGAATCTCCCAATCATCACTCGAGTCCCGTCTACCAAGTGTTTTCTTGATAAAAACAGTAAAAAAGTCA	Homo sapiens	hg19									
FGFR1_1.chr8.38282209.38282209_tile_1	FGFR1_1.chr8.38282209.38282209_tile_1	1	chr8	38282183	38282360	+	GGGGACCGCTCTGTGGAAGATGGGAGAGGAGGCACTTGTCATGGGGACCTTGCCATGGCTAAAGAGGGGTGGGCTCACCTGCGCCCCACTTGGCTTTCCCAGTGATGGGTTGTAAACCTCCCAGCAC	Homo sapiens	hg19									
FGFR1_2.chr8.38285938.38285938_tile_1	FGFR1_2.chr8.38285938.38285938_tile_1	1	chr8	38285908	38286090	+	TCCGAGGAGGGGAGAGCATCTATGGGAAGAAGAAGGGGCACTGAGGTTCCTCCTAGGGACCCCTAGATTTCACCAAGGCTAGTGCAGTTCCAGATGAACACGGACACCCTCCCCATGGGGATCCCAGTC	Homo sapiens	hg19									
JAK2_1.chr9.5073769.5073770_tile_1	JAK2_1.chr9.5073769.5073770_tile_1	1	chr9	5073737	5073923	+	TATGTGTCTGTGGAGACGAGAGTAAGTAAAACTACAGGCTTTCTAATGCCTTTCTCAGAGCATCTGTTTTTGTTTATATAGAAAATTCAGTTTCAGGATCACAGCTAGGTGTCAGTGTAAACTATAATTT	Homo sapiens	hg19									
CDKN2A1.chr9.21971153.21971187_tile_1	CDKN2A1.chr9.21971153.21971187_tile_1	1	chr9	21971123	21971308	+	GGGCTCCGCGCCGTGGAGCAGCAGCAGCTCCGCCACTCGGGCGCTGCCCATCATCATGACCTGCCAGAGAGAACAGAATGGTCAGAGCCAGGGTGGGGGCCGGCATGACGGAAAGGAAGCTTGTGTAGAGCCCCC	Homo sapiens	hg19									
ABL1_1.chr9.133738330.133738364_tile_1	ABL1_1.chr9.133738330.133738364_tile_1	1	chr9	133738302	133738491	+	CCATGAAGCACAAGCTGGGCGGGGGCCAGTACGGGGAGGTGTACGAGGGCGTGTGGAAGAAATACAGCCTGACGGTGGCCGTGAAGACCTTGAAGGTAGGCTGGGACTGCCGGGGGTGCCCAGGGTACGTGGGGCAAG	Homo sapiens	hg19									
ABL1_9.chr9.133747520.133747520_tile_1	ABL1_9.chr9.133747520.133747520_tile_1	1	chr9	133747476	133747664	+	TTTCCTTCTGCAGGAGGACACCATGGAGGTGGAAGAGTTCTTGAAAGAAGCTGCAGTCATGAAAGAGATCAAACACCCTAACCTGGTGCAGCTCCTTGGTGAGTAAGCCCGGGGCTCTGAAGAGAGGGTCTCGCGCCGC	Homo sapiens	hg19									
ABL1_10.chr9.133748283.133748414_tile_1	ABL1_10.chr9.133748283.133748414_tile_1	1	chr9	133748157	133748327	-	CCCGTAGGTCATGAACTCAGTGATGATATAGAACGGGGGCTCCCGGGTGCAGACCCCTGCCAACAAGACAACGAGGACTTCAACACGTGGCTCCGCTCCCAACTGAACAAACAACT	Homo sapiens	hg19									
ABL1_10.chr9.133748283.133748414_tile_2	ABL1_10.chr9.133748283.133748414_tile_2	1	chr9	133748277	133748457	+	GAACCTCCTGGACTACCTGAGGGAGTGCAACCGGCAGGAGGTGAACGCCGTGGTGCTGCTGTACATGGCCACTCAGATCTCGTCAGCCATGGAGTACCTGGAGAAGAAAAACTTCATCCACAGGTAGGGGCCT	Homo sapiens	hg19									
ABL1_16.chr9.133750356.133750356_tile_1	ABL1_16.chr9.133750356.133750356_tile_1	1	chr9	133750328	133750516	+	GCCCATGCTGGAGCCAAGTTCCCCATCAAATGGACTGCACCCGAGAGCCTGGCCTACAACAAGTTCTCCATCAAGTCCGACGTCTGGGGTAAGGGCTGCTGCTGCACTGAAGTGGTCCTTCCTGACTACAGGAGGGTT	Homo sapiens	hg19									
NOTCH1_1.chr9.139397768.139397768_tile_1	NOTCH1_1.chr9.139397768.139397768_tile_1	1	chr9	139397740	139397928	+	CCAGGTAGACGATGGAGCTGGGCGGACAATCAGAGAGGGGCTGGGACCCGAGGCTTCCTCCTCCCCCGCCCACCGGCCAGGGATGCTGCCGCAGGACACTGAGGCCCATGACGCCACAGTCAGGACATGGTGAGGC	Homo sapiens	hg19									
NOTCH1_2.chr9.139399344.139399422_tile_1	NOTCH1_2.chr9.139399344.139399422_tile_1	1	chr9	139399316	139399485	+	GCAGCACGCGGCTGAGCTCCCGCAGGAAGTGGAAGGAGCTGTTGCGCAGCTGCTCCGGCGGCATCAGCACCACCACCACCAGCGTGCCGGCCGCCAGCCTCTCGGGTACATGCTCCGC	Homo sapiens	hg19									
RET1.chr10.43609078.43609104_tile_1	RET1.chr10.43609078.43609104_tile_1	1	chr10	43609048	43609226	+	CTGCTTCCCTGAGGAGGAGAAGTGCTTCTGCGAGCCCGAAGACATCCAGGGTGAGTGGGTGGCGGCCGGGACCACCACCACCTCCCAGCCCCACAGAGGTCTCAACAGCACATCTGAGGTCCCAACAA	Homo sapiens	hg19									
RET2_9.chr10.43609940.43609950_tile_1	RET2_9.chr10.43609940.43609950_tile_1	1	chr10	43609902	43610075	-	TGGCTTGTGGGCAAACTTGTGGTAGCAGTGGATGCAGAAGGCAGACAGCAGCACCGAGACGATGAAGGAGAAGAGGACAGCGGCTGCGATCACCGTGCGGCACAGCTCGTCGCACAGTGG	Homo sapiens	hg19									
RET10.chr10.43613840.43613840_tile_1	RET10.chr10.43613840.43613840_tile_1	1	chr10	43613810	43613998	+	CGAGTGAGCTGCGAGACCTGCTGTCAGAGTTCAACGTCCTGAAGCAGGTCAACCACCCACATGTCATCAAATTGTATGGGGCCTGCAGCCAGGATGGTAAGGCCAGCTGCAGGGTGAGGTGGGCAGCCACTGCACCCAG	Homo sapiens	hg19									
RET11_12.chr10.43615567.43615569_tile_1	RET11_12.chr10.43615567.43615569_tile_1	1	chr10	43615533	43615703	+	CCTGGTAGCTGAGGGGCGGAAGATGAAGATTTCGGATTTCGGCTTGTCCCGAGATGTTTATGAAGAGGATTCCTACGTGAAGAGGAGCCAGGTGCCCAGTCCCGGGGATGAGGCGGGG	Homo sapiens	hg19									
RET13.chr10.43617416.43617416_tile_1	RET13.chr10.43617416.43617416_tile_1	1	chr10	43617388	43617564	+	ATGGCAATTGAATCCCTTTTTGATCATATCTACACCACGCAAAGTGATGTGTAAGTGTGGGTGTTGCTCTCTTGGGGTGGAGGTTACAGAAACACCCTTATACATGTAGTGGGGCCACGACGC	Homo sapiens	hg19									
PTEN1.chr10.89624242.89624244_tile_1	PTEN1.chr10.89624242.89624244_tile_1	1	chr10	89624214	89624388	+	CAAAGAGATCGTTAGCAGAAACAAAAGGAGATATCAAGAGGATGGATTCGACTTAGACTTGACCTGTATCCATTTCTGCGGCTGCTCCTCTTTACCTTTCTGTCACTCTCTTAGAACGTGG	Homo sapiens	hg19									
PTEN3.chr10.89685307.89685307_tile_1	PTEN3.chr10.89685307.89685307_tile_1	1	chr10	89685275	89685459	+	ATATACAATCTGTAAGTATGTTTTCTTATTTGTATGCTTGCAAATATCTTCTAAAACAACTATTAAGTGAAAGTTATCTGCTTGTTAGAGTGAGGTAGAGTTAAAGATACATTTTAACAGAATTGTATT	Homo sapiens	hg19									
PTEN4.chr10.89711893.89711900_tile_1	PTEN4.chr10.89711893.89711900_tile_1	1	chr10	89711865	89712039	+	GTCAGAGGCGCTATGTGTATTATTATAGCTACCTGTTAAAGAATCATCTGGATTATAGACCAGTGGCACTGTTGTTTCACAAGATGATGTTTGAAACTATTCCAATGTTCAGTGGCGGAACT	Homo sapiens	hg19									
PTEN7.chr10.89717615.89717772_tile_1	PTEN7.chr10.89717615.89717772_tile_1	1	chr10	89717489	89717668	+	ATATTGCTGATATTAATCATTAAAATCGTTTTTGACAGTTTGACAGTTAAAGGCATTTCCTGTGAAATAATACTGGTATGTATTTAACCATGCAGATCCTCAGTTTGTGGTCTGCCAGCTAAAG	Homo sapiens	hg19									
PTEN7.chr10.89717615.89717772_tile_2	PTEN7.chr10.89717615.89717772_tile_2	1	chr10	89717615	89717801	-	TTTAGCATCTTGTTCTGTTTGTGGAAGAACTCTACTTTGATATCACCACACACAGGTAACGGCTGAGGGAACTCAAAGTACATGAACTTGTCTTCCCGTCGTGTGGGTCCTGAATTGGAGGAATATATCTTCACC	Homo sapiens	hg19									
PTEN13.chr10.89720716.89720852_tile_1	PTEN13.chr10.89720716.89720852_tile_1	1	chr10	89720684	89720870	+	CAGAAAAAGTAGAAAATGGAAGTCTATGTGATCAAGAAATCGATAGCATTTGCAGTATAGAGCGTGCAGATAATGACAAGGAATATCTAGTACTTACTTTAACAAAAAATGATCTTGACAAAGCAAATAAAGACA	Homo sapiens	hg19									
PTEN13.chr10.89720716.89720852_tile_2	PTEN13.chr10.89720716.89720852_tile_2	1	chr10	89720814	89720991	-	TTCTTCATCAGCTGTACTCCTAGAATTAAACACACATCACATACATACAAGTCAACAACCCCCACAAAATGTTTAATTTAACTGACCTTAAAATTTGGAGAAAAGTATCGGTTGGCTTT	Homo sapiens	hg19									
FGFR2_1.chr10.123258034.123258034_tile_1	FGFR2_1.chr10.123258034.123258034_tile_1	1	chr10	123258006	123258184	+	GATTTATGATATTCTTGTGTTTCCCAATCATCTTCATCATCTCCATCTCTGACACCAGATCAGAAAGGTCTTTCTCTGTGGCATCATCTATGAACAGTAGGCATATTCACAAATCAGTTCATTTC	Homo sapiens	hg19									
FGFR2_2.chr10.123274774.123274803_tile_1	FGFR2_2.chr10.123274774.123274803_tile_1	1	chr10	123274746	123274930	+	CAGTAAATGGCTATCTCCAGGTAGTCTGGGGAAGCTGTAATCTCCTTTTCTCTTCCAGGCGCTAGATTGCAGATCACAGGAGGAGGAACAGATAAGCAGGCCATAGAGTTAGCACACCAGACTGACGCATC	Homo sapiens	hg19									
FGFR2_5.chr10.123279503.123279677_tile_1	FGFR2_5.chr10.123279503.123279677_tile_1	1	chr10	123279385	123279555	+	AACAGGAAATCAAAGAACCTGTGGCCAAACCCATGAAGGAGACCCCAGTTGTGGGTACCTTTAGATTCAGAAAGTCCTCACCTTGAGAACCTTGAGGTAGGGCAGCCCGTCGGGCCC	Homo sapiens	hg19									
FGFR2_5.chr10.123279503.123279677_tile_2	FGFR2_5.chr10.123279503.123279677_tile_2	1	chr10	123279471	123279640	-	ACGTAGAGTTTGTCTGCAAGGTTTACAGTGATGCCCAGCCCCACATCCAGTGGATCAAGCACGTGGAAAAGAACGGCAGTAAATACGGGCCCGACGGGCTGCCCTACCTCAAGGTT	Homo sapiens	hg19									
FGFR2_5.chr10.123279503.123279677_tile_3	FGFR2_5.chr10.123279503.123279677_tile_3	1	chr10	123279587	123279769	+	TCTCCTCCGACCACTGTGGAGGCATTTGCCGGCAGTCCGGCTTGGAGGATGGGCCGGTGAGGCGATCGCTCTGGTGGAGAGAGGGAAGAAAGGAGGAGTGGGGATGGGAGAATGAGAGACCAATAAATA	Homo sapiens	hg19									
HRAS1.chr11.533873.533875_tile_1	HRAS1.chr11.533873.533875_tile_1	1	chr11	533843	534021	+	CCTCCTGGCCGGCGGTATCCAGGATGTCCAACAGGCACGTCTCCCCATCAATGACCACCTGCTTCCGGTAGGAATCCTGCAGGAGGACAGGGCTCAGGGACCCCCTCAGGACCTTCCGTGGGGGGA	Homo sapiens	hg19									
HRAS6.chr11.534285.534289_tile_1	HRAS6.chr11.534285.534289_tile_1	1	chr11	534251	534434	+	GCCCACACCGCCGGCGCCCACCACCACCAGCTTATATTCCGTCATCGCTCCTCAGGGGCCTGCGGCCCGGGGTCCTCCTACAGGGTCTCCTGCCCCACCTGCCAAGGAGGGCCCTGCTCAGCCAGGCCCAGGC	Homo sapiens	hg19									
ATM1.chr11.108117847.108117848_tile_1	ATM1.chr11.108117847.108117848_tile_1	1	chr11	108117817	108117989	+	TGTCACCAGGTACAGTAAGTAGGTCATGTCACATTTAGAAATTTCCTGTTAATTTTTTTTTTAAACTGGGCATTTTGGGCTTTTAAAACCTGTGTTCTCACAAAAAGCCTATAAAAT	Homo sapiens	hg19									
ATM2.chr11.108119823.108119823_tile_1	ATM2.chr11.108119823.108119823_tile_1	1	chr11	108119793	108119963	+	TTGTGCCTTGGTAAAGTGTTACCATTTTCTCATTCAGTGTCATTTTAATCTCTTGTATGTTATTTTTCAGAAAACTTTCAGTGGAATCCTTTCATCTCAACCAGAACTAAGTCATTT	Homo sapiens	hg19									
ATM3.chr11.108123551.108123551_tile_1	ATM3.chr11.108123551.108123551_tile_1	1	chr11	108123513	108123683	+	AGTAATTTTCCTCATCTTGTACTGGAGAAAATTCTTGTGAGTCTCACTATGAAAAACTGTAAAGCTGCAATGAATTTTTTCCAAAGCGTGCCAGAATGGTATGTTATCTAATA	Homo sapiens	hg19									
ATM4.chr11.108137973.108138003_tile_1	ATM4.chr11.108137973.108138003_tile_1	1	chr11	108137939	108138126	+	TAATGGAGGTGGAGGATCAGTCATCCATGAATCTATTTAACGATTACCCTGATAGTAGTGTTAGTGATGCAAACGAACCTGGAGAGAGCCAAAGTACCATAGGTAAATACATATTTACTACTTGGGATT	Homo sapiens	hg19									
ATM6.chr11.108155132.108155132_tile_1	ATM6.chr11.108155132.108155132_tile_1	1	chr11	108155104	108155281	+	GGCACAGCAAAGAGAGACTGCTACCAAGGTCTATGATATGCTTAAAAGTGAAAACTTATTGGGAAAACAGGTATGGCTTCAATTTTTATGTACTTTTCATTCCCTGAATGATATGAGATAT	Homo sapiens	hg19									
ATM7.chr11.108170476.108170479_tile_1	ATM7.chr11.108170476.108170479_tile_1	1	chr11	108170442	108170618	+	GGGTCCTATAGATTTCTCTACCATAGCTATACAACATAGTAAAGATGCATCTTATACCAAGGCCCTTAAGTTATTTGAAGATAAAGAACTTCAGTGGACCTTCATAATGCTGACCTACCTGAA	Homo sapiens	hg19									
ATM9.chr11.108172421.108172421_tile_1	ATM9.chr11.108172421.108172421_tile_1	1	chr11	108172391	108172571	+	TTAGCCACAAAGACTGGACATAGTTTCTGGGAGATTTATAAGATGACAACAGATCCAATGCTGGCCTATCTACAGCCTTTTAGAACATCAAGAAAAAAGGTCTCTTAAGTAATAAATGTTTATTGAA	Homo sapiens	hg19									
ATM10.chr11.108173640.108173640_tile_1	ATM10.chr11.108173640.108173640_tile_1	1	chr11	108173612	108173801	+	AAATCTGTGGATTCCTCTAAGTGAAAATCATGACATTTGGATAAAGACACTGACTTGTGCTTTTTTGGACAGTGGAGGCACAAAATGTGAAATTCTTCAATTATTAAAGCCAATGTGTGAAGTAAGAAGATTAATT	Homo sapiens	hg19									
ATM11.chr11.108180945.108180945_tile_1	ATM11.chr11.108180945.108180945_tile_1	1	chr11	108180915	108181101	+	AAGTTGCCAAGGTAGCTCAGTCTTGTGCTGCTCACTTTACAGCTTTACTCTATGCAGAAATCTATGCAGATAAGAAAAGTATGGATGATCAAGAGAAAAGGTAATGGAATTTAGAATTTTTGGTTTTTAAAA	Homo sapiens	hg19									
ATM12.chr11.108200958.108200961_tile_1	ATM12.chr11.108200958.108200961_tile_1	1	chr11	108200926	108201096	+	TTCAGCGAGAGCTGGAGTTGGATGAATTAGCCCTGCGTGCACTGAAAGAGGATCGTAAACGCTTCTTATGTAAAGCAGTTGAAAATTATATCAACTGCTTATTAAGTGGAGAAGA	Homo sapiens	hg19									
ATM14.chr11.108204681.108204681_tile_1	ATM14.chr11.108204681.108204681_tile_1	1	chr11	108204651	108204823	+	TACTATGGAAATTAAGGTAATTTGCAATTAACTCTTGATTTTTTTTAAACTAAATTTTTTTTATTAGATTGAACCATTTGAAATAGTATTTTTATGTAGGTCAAAATTGGTTAAATA	Homo sapiens	hg19									
ATM15.chr11.108205769.108205769_tile_1	ATM15.chr11.108205769.108205769_tile_1	1	chr11	108205739	108205928	+	AGGTGTAAATTTACCAAAAATAATAGATTGTGTAGGTTCCGATGGCAAGGAGAGGAGACAGCTTGTTAAGGTGAGCCTTCCCTTCTCTGGCTTAGCCCTTAGAGTTTTAGTGATGAAAATTTTTAGTTCATATT	Homo sapiens	hg19									
ATM16.chr11.108206594.108206594_tile_1	ATM16.chr11.108206594.108206594_tile_1	1	chr11	108206566	108206750	+	GATGCTGTCATGCAACAGGTCTTCCAGATGTGTAATACATTACTGCAGAGAAACACGGAAACTAGGAAGAGGAAATTAACTATCTGTACTTATAAGGTAACTATTTGTACTTCTGTTAGTTCACCAAAAAC	Homo sapiens	hg19									
ATM17.chr11.108218089.108218089_tile_1	ATM17.chr11.108218089.108218089_tile_1	1	chr11	108218061	108218247	+	TCTAGGTAAGTAATAAAATCTATGTATCTATTCTTTTTAGTAAATATTTGGTCATCATGGAATGTTGTTTGCCTACCAAGATATTACAAATATAAGAGACAGATAAATTGAAGCAGTAAATATTGGGTTTTTT	Homo sapiens	hg19									
ATM18.chr11.108225590.108225590_tile_1	ATM18.chr11.108225590.108225590_tile_1	1	chr11	108225562	108225751	+	AACCATTGTAGAGGTAAAGTATTTTATAAGGAAGACTTTATTTTTTTTCTTACCAGGTAGACTGTGTATCTCATCAGGAAGTCACTGATGTGAAGAGCACTGCTTCATTTTAACATAGGGGGATGTGGCTGGGCAGC	Homo sapiens	hg19									
ATM19.chr11.108236086.108236203_tile_1	ATM19.chr11.108236086.108236203_tile_1	1	chr11	108236058	108236241	+	ACGTGTCTTAATGAGACTACAAGAGAAACTGAAAGGAGTGGAAGAAGGCACTGTGCTCAGTGTTGGTGGACAAGTGAATTTGCTCATACAGCAGGCCATAGACCCCAAAAATCTCAGCCGACTTTTCCCAG	Homo sapiens	hg19									
KRAS1.chr12.25378562.25378562_tile_1	KRAS1.chr12.25378562.25378562_tile_1	1	chr12	25378532	25378717	+	TTGCTGATGTTTCAATAAAAGGAATTCCATAACTTCTTGCTAAGTCCTGAGCCTGTTTTGTGTCTACTGTTCTAGAAGGCAAATCACATTTATTTCCTACTAGGACCATAGGTACATCTTCAGAGTCCTTA	Homo sapiens	hg19									
KRAS2.chr12.25380275.25380283_tile_1	KRAS2.chr12.25380275.25380283_tile_1	1	chr12	25380245	25380427	+	CCTCTTGACCTGCTGTGTCGAGAATATCCAAGAGACAGGTTTCTCCATCAATTACTACTTGCTTCCTGTAGGAATCCTGAGAAGGGAGAAACACAGTCTGGATTATTACAGTGCACCTTTTACTTCAA	Homo sapiens	hg19									
KRAS7.chr12.25398255.25398285_tile_1	KRAS7.chr12.25398255.25398285_tile_1	1	chr12	25398225	25398414	+	TGTATCGTCAAGGCACTCTTGCCTACGCCACCAGCTCCAACTACCACAAGTTTATATTCAGTCATTTTCAGCAGGCCTTATAATAAAAATAATGAAAATGTGACTATATTAGAACATGTCACACATAAGGTTA	Homo sapiens	hg19									
PTPN11_1.chr12.112888163.112888211_tile_1	PTPN11_1.chr12.112888163.112888211_tile_1	1	chr12	112888135	112888323	+	TGGTGATTACTATGACCTGTATGGAGGGGAGAAATTTGCCACTTTGGCTGAGTTGGTCCAGTATTACATGGAACATCACGGGCAATTAAAAGAGAAGAATGGAGATGTCATTGAGCTTAAATATCCTCTGAACTGT	Homo sapiens	hg19									
PTPN11_10.chr12.112926884.112926888_tile_1	PTPN11_10.chr12.112926884.112926888_tile_1	1	chr12	112926856	112927032	+	GGTCAGGGATGGTCCAGACAGAAGCACAGTACCGATTTATCTATATGGCGGTCCAGCATTATATTGAAACACTACAGCGCAGGATTGAAGAAGAGCAGGTACCAGCCTGAGGGCTGGCATGCGG	Homo sapiens	hg19									
HNF1A_1.chr12.121431413.121431414_tile_1	HNF1A_1.chr12.121431413.121431414_tile_1	1	chr12	121431385	121431558	+	GTGGGGCCCAGCATCCCAGCAGATCCTGTTCCAGGCCTATGAGAGGCAGAAGAACCCTAGCAAGGAGGAGCGAGAGACGCTAGTGGAGGAGTGCAATAGGTACAACGGCGGGCGGGAAACAG	Homo sapiens	hg19									
HNF1A_3.chr12.121432070.121432070_tile_1	HNF1A_3.chr12.121432070.121432070_tile_1	1	chr12	121432042	121432221	+	GCGCAAAGAAGAAGCCTTCCGGCACAAGCTGGCCATGGACACGTACAGCGGGCCCCCCCCAGGGCCAGGCCCGGGACCTGCGCTGCCCGCTCACAGCTCCCCTGGCCTGCCTCCACCTGCCCTCTCCCCC	Homo sapiens	hg19									
FLT3_1.chr13.28592620.28592653_tile_1	FLT3_1.chr13.28592620.28592653_tile_1	1	chr13	28592590	28592766	+	CATAGTTGGAATCACTCATGATATCTCGAGCCAATCCAAAGTCACATATCTTCACCACTTTCCCGTGGGTGACAAGCACGTTCCTGGCGGCCAGGTCTCTGTGAACACACTGTCAAGAATGA	Homo sapiens	hg19									
FLT3_13.chr13.28602329.28602329_tile_1	FLT3_13.chr13.28602329.28602329_tile_1	1	chr13	28602295	28602464	+	GTGTGCACGCCCCCAGCAGGTTCACAATATTCTCGTGGCTTCCCAGCTGGGTCATCATCTTGAGTTCTGACATGAGTGCCTCTCTTTCAGAGCTGTCTGCTTTTTCTGTCAAAGAA	Homo sapiens	hg19									
FLT3_14.chr13.28608244.28608341_tile_1	FLT3_14.chr13.28608244.28608341_tile_1	1	chr13	28608214	28608402	+	ACTCCCATTTGAGATCATATTCATATTCTCTGAAATCAACGTAGAAGTACTCATTATCTGAGGAGCCGGTCACCTGTACCATCTGTAGCTGGCTTTCATACCTAAATTGCTTCAGAGATGAAATGATGAGTCA	Homo sapiens	hg19									
FLT3_22.chr13.28610138.28610138_tile_1	FLT3_22.chr13.28610138.28610138_tile_1	1	chr13	28610098	28610267	-	TATAGGAGTGAACCACTATGCCCAGCCAGTGAGCTTATTTCACACGTTCTTTTCTATAGGGAAACCTCAAGTGCTCGCAGAAGCATCGGCAAGTCAGGCGTCCTGTTTCTCGGATGG	Homo sapiens	hg19									
RB1_1.chr13.48919244.48919244_tile_1	RB1_1.chr13.48919244.48919244_tile_1	1	chr13	48919156	48919336	+	ATTTACTTTTTTCTATTCTTTCCTTTGTAGTGTCCATAAATTCTTTAACTTACTAAAAGAAATTGATACCAGTACCAAAGTTGATAATGCTATGTCAAGACTGTTGAAGAAGTATGATGTATTG	Homo sapiens	hg19									
RB1_2.chr13.48923148.48923148_tile_1	RB1_2.chr13.48923148.48923148_tile_1	1	chr13	48923120	48923296	+	TTATTAGCTAAAGGTAAGTTCATTATATTTATTAAATGCTAATATTTCAAATGTAATAATTAAATTGGCATTCCTTTGGACTAAATTCCCCAATTTTTATTGAGTAATGTACTCCTCCCTCAT	Homo sapiens	hg19									
RB1_3.chr13.48942685.48942685_tile_1	RB1_3.chr13.48942685.48942685_tile_1	1	chr13	48942655	48942826	+	ACGAAAAAGTAACCTTGATGAAGAGGTGAATGTAATTCCTCCACACACTCCAGTTAGGTATGAATTTTCCTACTTTTAATTATATTATAATTTTGTTATTCATGGCTTTATAGTG	Homo sapiens	hg19									
RB1_4.chr13.48955538.48955550_tile_1	RB1_4.chr13.48955538.48955550_tile_1	1	chr13	48955504	48955684	+	TAGAACGATGTGAACATCGAATCATGGAATCCCTTGCATGGCTCTCAGTAAGTAGCTAAATAATTGAAGAAATTCATTCATGTGCATATGGCTAACAAATTATTGTTAGTGAGAGGTGTTTCTTA	Homo sapiens	hg19									
RB1_6.chr13.49027168.49027168_tile_1	RB1_6.chr13.49027168.49027168_tile_1	1	chr13	49027112	49027288	+	TTTGATCTTATTAAACAATCAAAGGACCGAGAAGGACCAACTGATCACCTTGAATCTGCTTGTCCTCTTAATCTTCCTCTCCAGAATAATCACACTGCAGCAGATATGTAAGCAAAATATA	Homo sapiens	hg19									
RB1_7.chr13.49033843.49033846_tile_1	RB1_7.chr13.49033843.49033846_tile_1	1	chr13	49033813	49033989	+	TCTCCGGCTAAATACACTTTGTGAACGCCTTCTGTCTGAGCACCCAGAATTAGAACATATCATCTGGACCCTTTTCCAGCACACCCTGCAGAATGAGTATGAACTCATGAGAGACAGGCATTT	Homo sapiens	hg19									
RB1_8.chr13.49037877.49037877_tile_1	RB1_8.chr13.49037877.49037877_tile_1	1	chr13	49037815	49037985	+	TTTACATCAATTTATTTACTAGATTATGATGTGTTCCATGTATGGCATATGCAAAGTGAAGAATATAGACCTTAAATTCAAAATCATTGTAACAGCATACAAGGATCTTCCTCA	Homo sapiens	hg19									
RB1_9.chr13.49039164.49039164_tile_1	RB1_9.chr13.49039164.49039164_tile_1	1	chr13	49039132	49039304	+	AAGAGGAGTATGATTCTATTATAGTATTCTATAACTCGGTCTTCATGCAGAGACTGAAAACAAATATTTTGCAGTATGCTTCCACCAGGGTAGGTCAAAAGTATCCTTTGATTGGAAAA	Homo sapiens	hg19									
AKT1.chr14.105246455.105246455_tile_1	AKT1.chr14.105246455.105246455_tile_1	1	chr14	105246429	105246600	+	CTCACGTTGGTCCACATCCTGCGGCCGCTCCTTGTAGCCAATGAAGGTGCCATCATTCTTGAGGAGGAAGTAGCGTGGCCGCCAGGTCTTGATGTACTCCCCTACAGACGTGCGGGTGGTGA	Homo sapiens	hg19									
CDH1_1.chr16.68835649.68835650_tile_1	CDH1_1.chr16.68835649.68835650_tile_1	1	chr16	68835613	68835782	+	TGGGCACAGATGGTGTGATTACAGTCAAAAGGCCTCTACGGTTTCATAACCCACAGATCCATTTCTTGGTCTACGCCTGGGACTCCACCTACAGAAAGTTTTCCACCAAAGTCACGCTGAAT	Homo sapiens	hg19									
CDH1_2.chr16.68846137.68846137_tile_1	CDH1_2.chr16.68846137.68846137_tile_1	1	chr16	68846109	68846283	+	CGATAATCCTCCGATCTTCAATCCCACCACGGTAATTCTATAACTCCTTAGAGGGTTTCCAAAGAAAGGTCTTTTGTTGTTCATGAACTAAGTGTCACCACTGCTCATGGGCGAAGTCTTT	Homo sapiens	hg19									
CDH1_3.chr16.68847274.68847277_tile_1	CDH1_3.chr16.68847274.68847277_tile_1	1	chr16	68847246	68847422	+	ACTGATGCTGATGCCCCCAATACCCCAGCGTGGGAGGCTGTATACACCATATTGAATGATGATGGTGGACAATTTGTCGTCACCACAAATCCAGTGAACAACGATGGCATTTTGAAAACAGCA	Homo sapiens	hg19									
TP53_1.chr17.7574003.7574021_tile_1	TP53_1.chr17.7574003.7574021_tile_1	1	chr17	7573977	7574147	+	CGGAACATCTCGAAGCGCTCACGCCCACGGATCTGCAGCAACAGAGGAGGGGGAGAAGTAAGTATATACACAGTACCTGAGTTAAAAGATGGTTCAAGTTACAATTGTTTGACTTTATG	Homo sapiens	hg19									
TP53_3.chr17.7577022.7577129_tile_1	TP53_3.chr17.7577022.7577129_tile_1	1	chr17	7576996	7577166	+	CGCTTAGTGCTCCCTGGGGGCAGCTCGTGGTGAGGCTCCCCTTTCTTGCGGAGATTCTCTTCCTCTGTGCGCCGGTCTCTCCCAGGACAGGCACAAACACGCACCTCAAAGCTGTTCCG	Homo sapiens	hg19									
TP53_17.chr17.7577523.7577574_tile_1	TP53_17.chr17.7577523.7577574_tile_1	1	chr17	7577495	7577683	+	GGTGAGGATGGGCCTCCGGTTCATGCCGCCCATGCAGGAACTGTTACACATGTAGTTGTAGTGGATGGTGGTACAGTCAGAGCCAACCTAGGAGATAACACAGGCCCAAGATGAGGCCAGTGCGCCTTGGGGAGA	Homo sapiens	hg19									
TP53_31_59.chr17.7578190.7578536_tile_1	TP53_31_59.chr17.7578190.7578536_tile_1	1	chr17	7578064	7578234	+	AGAAAGCCCCCCTACTGCTCACCTGGAGGGCCACTGACAACCACCCTTAACCCCTCCTCCCAGAGACCCCAGTTGCAAACCAGACCTCAGGCGGCTCATAGGGCACCACCACACTA	Homo sapiens	hg19									
TP53_31_59.chr17.7578190.7578536_tile_2	TP53_31_59.chr17.7578190.7578536_tile_2	1	chr17	7578156	7578325	-	CTGATTGCTCTTAGGTCTGGCCCCTCCTCAGCATCTTATCCGAGTGGAAGGAAATTTGCGTGTGGAGTATTTGGATGACAGAAACACTTTTCGACATAGTGTGGTGGTGCCCTATGAGCCGCC	Homo sapiens	hg19									
TP53_31_59.chr17.7578190.7578536_tile_3	TP53_31_59.chr17.7578190.7578536_tile_3	1	chr17	7578246	7578415	+	TGAGGAGGGGCCAGACCTAAGAGCAATCAGTGAGGAATCAGAGGCCTGGGGACCCTGGGCAACCAGCCCTGTCGTCTCTCCAGCCCCAGCTGCTCACCATCGCTATCTGAGCAGCG	Homo sapiens	hg19									
TP53_31_59.chr17.7578190.7578536_tile_4	TP53_31_59.chr17.7578190.7578536_tile_4	1	chr17	7578346	7578515	-	GTTGATTCCACACCCCCGCCCGGCACCCGCGTCCGCGCCATGGCCATCTACAAGCAGTCACAGCACATGACGGAGGTTGTGAGGCGCTGCCCCCACCATGAGCGCTGCTCAGATAGCG	Homo sapiens	hg19									
TP53_31_59.chr17.7578190.7578536_tile_5	TP53_31_59.chr17.7578190.7578536_tile_5	1	chr17	7578468	7578645	+	CCCACAGCTGCACAGGGCAGGTCTTGGCCAGTTGGCAAAACATCTTGTTGAGGGCAGGGGAGTACTGTAGGAAGAGGAAGGAGACAGAGTTGAAAGTCAGGGCACAAGTGAACAGATAAAGCAACTGGA	Homo sapiens	hg19									
TP53_60.chr17.7579358.7579403_tile_1	TP53_60.chr17.7579358.7579403_tile_1	1	chr17	7579324	7579507	+	GCCCAGACGGAAACCGTAGCTGCCCTGGTAGGTTTTCTGGGAAGGGACAGAAGATGACAGGGGCCAGGAGGGGGCTGGTGCAGGGGCCGCCGGTGTAGGAGCTGCTGGTGCAGGGGCCACGGGGGGAGCAG	Homo sapiens	hg19									
TP53_64.chr17.7579882.7579882_tile_1	TP53_64.chr17.7579882.7579882_tile_1	1	chr17	7579852	7580032	+	GCTCGACGCTAGGATCTGACTGCGGCTCCTCCATGGCAGTGACCCGGAAGGCAGTCTGGCTGCTGCAAGAGGAAAAGTGGGGATCCAGCATGAGACACTTCCAACCCTGGGTCACCTGGGCCTGCAG	Homo sapiens	hg19									
ERBB2_1.chr17.37880219.37880261_tile_1	ERBB2_1.chr17.37880219.37880261_tile_1	1	chr17	37880191	37880361	+	TGTTGAGGGAAAACACATCCCCCAAAGCCAACAAAGAAATCTTAGACGTAAGCCCCTCCACCCTCTCCTGCTAGGAGGACAGGAAGGACCCCATGGCTGCAGGTCTGGGCTCTGGTCT	Homo sapiens	hg19									
ERBB2_4.chr17.37880993.37881012_tile_1	ERBB2_4.chr17.37880993.37881012_tile_1	1	chr17	37880963	37881151	+	CGTGATGGCTGGTGTGGGCTCCCCATATGTCTCCCGCCTTCTGGGCATCTGCCTGACATCCACGGTGCAGCTGGTGACACAGCTTATGCCCTATGGCTGCCTCTTAGACCATGTCCGGGAAAACCGCGGACGCCTGGG	Homo sapiens	hg19									
ERBB2_13.chr17.37881332.37881440_tile_1	ERBB2_13.chr17.37881332.37881440_tile_1	1	chr17	37881298	37881482	+	GCGGCTCGTACACAGGGACTTGGCCGCTCGGAACGTGCTGGTCAAGAGTCCCAACCATGTCAAAATTACAGACTTCGGGCTGGCTCGGCTGCTGGACATTGACGAGACAGAGTACCATGCAGATGGGGGCA	Homo sapiens	hg19									
SMAD4_1.chr18.48575169.48575170_tile_1	SMAD4_1.chr18.48575169.48575170_tile_1	1	chr18	48575131	48575301	+	TTTGACTTAAAATGTGATAGTGTCTGTGTGAATCCATATCACTACGAACGAGTTGTATCACCTGGAATTGGTAAGTAGACTTTGCTTTCATCCTAAGAAACATAAAGGGAAA	Homo sapiens	hg19									
SMAD4_2.chr18.48581198.48581198_tile_1	SMAD4_2.chr18.48581198.48581198_tile_1	1	chr18	48581168	48581346	+	AGGGACAGCCATCGTTGTCCACTGAAGGACATTCAATTCAAACCATCCAGCATCCACCAAGTAATCGTGCATCGACAGAGACATACAGCACCCCAGCTCTGTTAGCCCCATCTGAGTCTAATGC	Homo sapiens	hg19									
SMAD4_3.chr18.48584560.48584560_tile_1	SMAD4_3.chr18.48584560.48584560_tile_1	1	chr18	48584528	48584714	+	GGGCCTCAGCCAGGACAGCAGCAGAATGGATTTACTGGTCAGCCAGCTACTTACCATCATAGTATGTACATACTTTAAAAAATCTTTTAAATAGTTGAGAAAAAAGTAGGCAGCCTTTATAAAAGCAAATTAAC	Homo sapiens	hg19									
SMAD4_4.chr18.48586262.48586262_tile_1	SMAD4_4.chr18.48586262.48586262_tile_1	1	chr18	48586234	48586416	+	CCAGCCTCCCATTTCCAATCATCCTGGTAAGTGTATTTCAAAATTGATTTCCTGTATTTAGATTGATTTAGTGGTGATTGAAACGCACAAACACAGGCTTTAATGGAATTATGGGGTCACTTCTCAGAT	Homo sapiens	hg19									
SMAD4_5.chr18.48591826.48591919_tile_1	SMAD4_5.chr18.48591826.48591919_tile_1	1	chr18	48591796	48591982	+	TTGAAATGGATGTTCAGGTAGGAGAGACATTTAAGGTTCCTTCAAGCTGCCCTATTGTTACTGTTGATGGATACGTGGACCCTTCTGGAGGAGATCGCTTTTGTTTGGGTCAACTCTCCAATGTCCACAGGAC	Homo sapiens	hg19									
SMAD4_11.chr18.48593405.48593405_tile_1	SMAD4_11.chr18.48593405.48593405_tile_1	1	chr18	48593377	48593547	+	AAGGTGTGCAGTTGGAATGTAAAGGTGAAGGTGATGTTTGGGTCAGGTGCCTTAGTGACCACGCGGTCTTTGTACAGAGTTACTACTTAGACAGAGAAGCTGGGCGTGCACCTGGAGA	Homo sapiens	hg19									
SMAD4_12.chr18.48603032.48603094_tile_1	SMAD4_12.chr18.48603032.48603094_tile_1	1	chr18	48602998	48603168	+	TGTCATCGACAGATGCAGCAGCAGGCGGCTACTGCACAAGCTGCAGCAGCTGCCCAGGCAGCAGCCGTGGCAGGAAACATCCCTGGCCCAGGATCAGTAGGTGGAATAGCTCCA	Homo sapiens	hg19									
SMAD4_15.chr18.48604668.48604754_tile_1	SMAD4_15.chr18.48604668.48604754_tile_1	1	chr18	48604638	48604808	+	CGTCGCTTATGCATACTCAGGATGAGTTTTGTGAAAGGCTGGGGACCGGATTACCCAAGACAGAGCATCAAAGAAACACCTTGCTGGATTGAAATTCACTTACACCGGGCCCTCCAGC	Homo sapiens	hg19									
STK11_1.chr19.1207021.1207092_tile_1	STK11_1.chr19.1207021.1207092_tile_1	1	chr19	1206993	1207169	+	CCAGCCGCGCCGCAAGCGGGCCAAGCTCATCGGCAAGTACCTGATGGGGGACCTGCTGGGGGAAGGCTCTTACGGCAAGGTGAAGGAGGTGCTGGACTCGGAGACGCTGTGCAGGAGGGCCGT	Homo sapiens	hg19									
STK11_4.chr19.1220487.1220502_tile_1	STK11_4.chr19.1220487.1220502_tile_1	1	chr19	1220459	1220638	+	CCGACCTGGGCGTGGCCGAGGTAGGCACGTGCTAGGGGGGGCCCTGGGGCGCCCCCTCCCGGGCACTCCCTGAGGGCTGCACGGCACCGCCACAGGCACTGCACCCGTTCGCGGCGGACGACACCTGCCG	Homo sapiens	hg19									
STK11_8.chr19.1221264.1221319_tile_1	STK11_8.chr19.1221264.1221319_tile_1	1	chr19	1221232	1221407	-	CCCGCCTCCCTGGGGCTGCGGGCAGAGGGATGAGGCTCCCACCTTTCAGCAGGTCAGAGAGCGGGGGGCCACAGTCGCCCGGGATGGCGTAGCTCCCCTTCCCGATGTTCTCAAACAACTTG	Homo sapiens	hg19									
STK11_12.chr19.1223059.1223125_tile_1	STK11_12.chr19.1223059.1223125_tile_1	1	chr19	1223035	1223221	+	GGCGCAGCATGACTGTGGTGCCGTACTTGGAGGACCTGCACGGCGCGGACGAGGACGAGGACCTCTTCGACATCGAGGATGACATCATCTACACTCAGGACTTCACGGTGCCCGGTGAGTCTGGCGGGGGCCCCTGCCC	Homo sapiens	hg19									
JAK3_1.chr19.17945696.17945696_tile_1	JAK3_1.chr19.17945696.17945696_tile_1	1	chr19	17945666	17945840	+	GGTGACGCCACTAAACACTTCCCAGACCGTGGCGCCGAAGCCCCACTTGTCAGCTTCCAAGCTAAGTGTCTGCGCCTCCCGGAGACACTCGGGGGCCACCCAGGGGATCCTGTCGGTGAGCAC	Homo sapiens	hg19									
JAK3_2.chr19.17948009.17948009_tile_1	JAK3_2.chr19.17948009.17948009_tile_1	1	chr19	17947981	17948169	+	CGCTGCTTCCAGGAATGACTGGGGAAGGTGGGAAGGGAGAGAAGATGCGTGGGTTTCTTCCACTCCAATAATCCCAAATTTTGTGCTCACAGACCTGCCTTAGGGGAACACCTGGCCACAGGTCACCTTTGGCCCTGG	Homo sapiens	hg19									
SRC.chr20.36031762.36031762_tile_1	SRC.chr20.36031762.36031762_tile_1	1	chr20	36031734	36031923	+	CCAGCCCGGGGAGAACCTCTAGGCACAGGCGGGCCCAGACCGGCTTCTCGGCTTGGATCCTGGGCTGGGTGGCCCCTGTCTCGGGGCTTGCCCCACTCTGCCTGCCTGCTGTTGGTCCTCTCTCTGTGGGGCTGA	Homo sapiens	hg19									
GNAS1.chr20.57484420.57484421_tile_1	GNAS1.chr20.57484420.57484421_tile_1	1	chr20	57484390	57484560	+	TGCCGTGTCCTGACTTCTGGAATCTTTGAGACCAAGTTCCAGGTGGACAAAGTCAACTTCCAGTAAGCCAACTGTTACCTTTTTATATAACAGAGATCATGGTTTCTTGACATTCAC	Homo sapiens	hg19									
SMARCB1_1.chr22.24133967.24133990_tile_1	SMARCB1_1.chr22.24133967.24133990_tile_1	1	chr22	24133939	24134126	+	TCCGAGGTTCTCTGTACAAGAGATACCCCTCACTCTGGAGGCGACTAGCCACTGTGGAAGAGAGGAAGAAAATAGTTGCATCGTCACATGGTAAAAAAACAAAACCTAACACTAAGGGTGCGTCTTCACGAGGGTT	Homo sapiens	hg19									
SMARCB1_3.chr22.24143240.24143240_tile_1	SMARCB1_3.chr22.24143240.24143240_tile_1	1	chr22	24143210	24143383	+	GGGCCGAGACAAGAAGAGAACCTTCCCCCTTTGGTGTGGATGCATCGCTGCACTCACCCTCCGTGCTGATTCCGCCTTAGTTCTCCAGCACGTTTCAGTTCCTTCCTCCCCAGAAAAACACT	Homo sapiens	hg19									
SMARCB1_4.chr22.24145582.24145582_tile_1	SMARCB1_4.chr22.24145582.24145582_tile_1	1	chr22	24145552	24145726	+	GCTGCGAGACGCCTTCACCTGGAACATGAATGGTACAAGGCAGTCGGGCTTGGCTGGGCCTGGCCCCAACCCCTGTGTGTTACGTGGGAACAGTCCCGTTTCCTGCCAGCTGCCTGTCAGGC	Homo sapiens	hg19									
SMARCB1_5_6.chr22.24176352.24176357_tile_1	SMARCB1_5_6.chr22.24176352.24176357_tile_1	1	chr22	24176324	24176495	+	CGGCCCCGGCCTGGTAACCAGCCCATCAGCACACGGCTCCCACGGAGCATCTCAGAAGATTGGGCCGCCTCTCCTCCATCTTCTGGCAAGGACAGAGGCGAGGGGACAGCCCAGCGCCA	Homo sapiens	hg19									
GNA11_4.chr19.3114942.3115070_tile_1	GNA11_4.chr19.3114942.3115070_tile_1	1	chr19	3114824	3115004	-	GTAGCCCAAGGTGGCGATGCGGTCAACGTCGGTCAGGTAGCTGCAACACAGCGGTGGGTGCTCAGGCCGGCTGCCGGGGGTGGGGGGGCAGGACAGGGACACAGCACCCAAACCAGCGGGAGGACGGAAAGCCACC	Homo sapiens	hg19									
GNA11_4.chr19.3114942.3115070_tile_2	GNA11_4.chr19.3114942.3115070_tile_2	1	chr19	3114958	3115133	+	CCTGCCCACCCAGCAGGACGTGCTGCGGGTCCGCGTGCCCACCACCGGCATCATCGAGTACCCTTTCGACCTGGAGAACATCATCTTCCGGTACCGCCCGGGCCACAGCAGGCGGGGAGGGGGCACTGAGA	Homo sapiens	hg19									
GNA11_5.chr19.3118922.3119051_tile_1	GNA11_5.chr19.3118922.3119051_tile_1	1	chr19	3118802	3118989	-	CACTTCCTCCGCTCCGACCGCTGGCCCCCCACATCCACCATCCTGAAAGGACACAGCGCCAGGACTCAGCCACCTGGCGCCCCAAGGCCCAATCTGCAATCCCAGGACGGCTCCCACCCAAGCCCCTCCTGCCACACC	Homo sapiens	hg19									
GNA11_6.chr19.3119204.3119357_tile_2	GNA11_6.chr19.3119204.3119357_tile_2	1	chr19	3119208	3119395	-	CCGCAGCCCGGCGCACCATCGAACTCGGGGAAGTAGTCCACCAGGTGCGAGTACAGGATCTTGTCCTCCAGCAGGTCCTTCTTGTTGAGGAAGAGGATGACGGAGGAGTTCTGGAACCAGGGGTAGGTGATGATGGTCCGG	Homo sapiens	hg19									
GNA11_7.chr19.3120987.3121177_tile_1	GNA11_7.chr19.3120987.3121177_tile_1	1	chr19	3120865	3121035	+	GGGCCTTACTCGCTCATCCCCTGGGAGTGACAAAGGGGCCCACGAGTCCCTTGCCCTGGGCCGGGCTGGGGCACAGCCTCACCCTCTGCCCTCCCCCAGGTCCCCAGCGGGACGCCCAGGC	Homo sapiens	hg19									
GNA11_7.chr19.3120987.3121177_tile_2	GNA11_7.chr19.3120987.3121177_tile_2	1	chr19	3120985	3121170	-	CAGGATGGTGTCCTTCACGGCCGCGAACACGAAGCGGATGTTCTCCGTGTCGGTGGCACACGTGAAGTGTGAGTAGATGATCTTGTCGCTGTCGGGGTTCAGGTCCACGAACATCTTCAGGATGAACTCCCGCGCCGC	Homo sapiens	hg19									
GNA11_7.chr19.3120987.3121177_tile_3	GNA11_7.chr19.3120987.3121177_tile_3	1	chr19	3121121	3121304	+	GCAGCTCAACCTCAAGGAGTACAACCTGGTCTGAGCGCCCAGGCCCAGGGAGACGGGATGGAGACACGGGGCAGGACCTTCCTTCCACGGAGCCTGCGGCTGCCGGGCGGGTGGCGCTGCCGAGTCCGGGCCGGGGC	Homo sapiens	hg19									
GNAQ_4.chr9.80412436.80412564_tile_1	GNAQ_4.chr9.80412436.80412564_tile_1	1	chr9	80412406	80412592	+	TACCTGAAAATGACACTTTGTAAGTCAAAGGGGTATTCGATGATCCCTGTGGTGGGGACTCGAACTCTAAGCACATCTTGTTGCGTAGGCAGGTAGGCAGGGTCAGCTACGCGGTCCAAGTCATTAAGATAGC	Homo sapiens	hg19									
GNAQ_5.chr9.80409379.80409508_tile_1	GNAQ_5.chr9.80409379.80409508_tile_1	1	chr9	80409249	80409421	+	AAAGAAGTAAGTTCACTCCATTCCCCACACCCTACTTTCTATCATTTACTTGTATCAGATAATAAAATGATAATCCATTGCCTGTCTAAAGAACACTTACCTCATTGTCTGACT	Homo sapiens	hg19									
GNAQ_5.chr9.80409379.80409508_tile_2	GNAQ_5.chr9.80409379.80409508_tile_2	1	chr9	80409335	80409510	-	AGGTCAGAGAGAAGAAAATGGATACACTGCTTTGAAAATGTCACCTCTATCATGTTTCTAGTAGCGCTTAGTGAATATGATCAAGTTCTCGTGGAGTCAGACAATGAGGTAAGTGTTCTTTA	Homo sapiens	hg19									
GNAQ_5.chr9.80409379.80409508_tile_3	GNAQ_5.chr9.80409379.80409508_tile_3	1	chr9	80409459	80409639	+	TTTGGCCCCCTACATCGACCATTCTGCAAGGTTAACAATACTCATATTAATAACATATAAAGTAAAACTAAAAAGTCAACATAAATATAGCACTACTTACAAACTTAGGGAAAATATTCTCTTGAAT	Homo sapiens	hg19									
GNAQ_6.chr9.80343430.80343583_tile_1	GNAQ_6.chr9.80343430.80343583_tile_1	1	chr9	80343306	80343476	+	GGGCAGCAATGGTGCACTGTAGTGCGTTAACTCCCACACTGGGGTTTGGAGACAAAACCTATTCACAGCTACTGAGCTGTGGTATGAGTGCTGACTTACCATCATATTCTGGGAAGT	Homo sapiens	hg19									
GNAQ_6.chr9.80343430.80343583_tile_2	GNAQ_6.chr9.80343430.80343583_tile_2	1	chr9	80343392	80343561	-	GGTTCCAGAACTCCTCGGTTATTCTGTTCTTAAACAAGAAAGATCTTCTAGAGGAGAAAATCATGTATTCCCATCTAGTCGACTACTTCCCAGAATATGATGGTAAGTCAGCAC	Homo sapiens	hg19									
GNAQ_6.chr9.80343430.80343583_tile_3	GNAQ_6.chr9.80343430.80343583_tile_3	1	chr9	80343504	80343689	+	CAGGGGTATGTGATAATTGTTCTAAAGAGAGCCTTGCTTTCCTCCATTCGGTTCTGGAAAAAAAAAAAAAATCAGAAAAAACAAGGAGTGAATTACATGATTACTTAATTTGTGAATTGTGTTTATTTT	Homo sapiens	hg19									
GNAQ_7.chr9.80336240.80336429_tile_1	GNAQ_7.chr9.80336240.80336429_tile_1	1	chr9	80336110	80336280	+	TTAGTATTATGCAAATTGTTTTCCACAGAAATACAGTCCCTCTTGTGTATCTTCAATAGCCCACCAGGGAAGGGCAGGGCGGGTGTCTAGGAGGCACAATTAGACCAGATTGTACT	Homo sapiens	hg19									
GNAQ_7.chr9.80336240.80336429_tile_2	GNAQ_7.chr9.80336240.80336429_tile_2	1	chr9	80336204	80336374	-	CTACTCCCACTTCACGTGCGCCACAGACACCGAGAATATCCGCTTTGTCTTTGCTGCCGTCAAGGACACCATCCTCCAGTTGAACCTGAAGGAGTACAATCTGGTCTAATTGTGCCTCC	Homo sapiens	hg19									
GNAQ_7.chr9.80336240.80336429_tile_3	GNAQ_7.chr9.80336240.80336429_tile_3	1	chr9	80336320	80336495	+	GATAATTTTGTCACTGTCTGGGTTCAGGTCCACGAACATCTTCAGAATGAATTCTCGGGCTGCCTGGGCATCTCTCTGGGGTCCTTTCGGCCAAGAGACAAGAGGGACACTTTGTTACCTA	Homo sapiens	hg19									
PIK3CA4_11.chr3.178936074.178936095_tile_1	PIK3CA4_11.chr3.178936074.178936095_tile_1	2	chr22	17052964	17053133	+	ATCCTCTCTCTGAAATCACTGCGCAGGAGAAAGATTTTCTATGGACCACAGGTAAGTGCTAAAATGGAGATTCTCTGTTTCTTTTTCTTTATTACAGAAAAAATAACTGACTTTGG	Homo sapiens	hg19									
PIK3CA12.chr3.178938860.178938860_tile_1	PIK3CA12.chr3.178938860.178938860_tile_1	2	chr22	17055413	17055585	+	CACCTGAATAGGCAAGTCGAGGCAATGGAAAAGCTCATTAACTTAACTGACATTGTCAAACAGGAGAAGAAGGATGAAACACAAAAGTTGTGTGACTCTAGTCTGTGTTTGAGACTCTT	Homo sapiens	hg19									
PTEN7.chr10.89717615.89717772_tile_1	PTEN3.chr10.89685307.89685307_tile_1	2	chr9	33675957	33676480	-	ATACACAATCTTTGTGCTGAAAGACATTATGACACCGCCAAATCTAATTACAGAGTTGCGCAATATCCTTTTGAAGACCATAACCCACCACAGCTAGAACTTATCAAACCCTTTTGTGAAGATCTTGACCAATGGCTAAGTGAAGATGACAATCATGTTGCAGCAATTCACTGTAAAGCTGGAAAGGGACGAACTGGTATAATGATTTATGCATATTTATTACATCGGGGCAAATTTTTAAAGGCACAAGAGGCCCTAGATTTCTATGGGGAAGTAAGGACCAGAGACAAAAAGGGAGTAACTATTCCCAGTCAGAGGCGCTATGTGTATTACTATAGCTACCTGGTAAAGAATCATGTGGATTATAGACCAGTGGCACTGTTGTTTCACAAGATGATGTTTGAAACTATTCCAATGTTCAGTGGCGGAACTTGCAATCCTCAGTTTGTGGTCTGCCAGCTAAAG	Homo sapiens	hg19									
PTEN13.chr10.89720716.89720852_tile_1	PTEN13.chr10.89720716.89720852_tile_1	2	chr9	33675629	33675815	-	CAGAAAAAGTAGAAAATGGAAGTCTATGTGATCAAGAAATTGATAGCATTTGCAGTATAGAGCGTGCAGATAATGACAAGGAGTATCTAGTACTTACTTTAACAAAAAATGATCTTGACAAAGCAAATAAAGACA	Homo sapiens	hg19									
GNA11_6.chr19.3119204.3119357_tile_2	GNA11_7.chr19.3120987.3121177_tile_2	2	chr7	65970150	65970483	+	CAGGATGGTGTCCTTCACGGCCGCGAACACGAAGCGGATGTTCTTCGTGTCGGTGGCGTACGTGAAGTGGGAGTCGATGATCTTGTCGCTGTCGGGGTTCATGTCCACTAACATCTTCAGGATGAACTCCCGCGCCGCCTGGGCGTCCTGCTGGGGCCCTTCGAACTCGGGGAAGTAGTCCACCATGTGTGAGTACAGGATATTGTCCTCCAGCAGGTCCTTCTTGTTGAGGAAGGTGATGACGGGGGAGTTCTGGAACCAGGGGTAGTCGATGATGGTCCGG	Homo sapiens	hg19									
GNA11_7.chr19.3120987.3121177_tile_1	GNA11_4.chr19.3114942.3115070_tile_2	2	chr7	65970285	65970719	-	CCTGCCCACCCAGCAGGACGTGCTGCGGGTCCGCGTGCCCACCACCGGCGTCTTTCGACCTGGAGAACATCATCTTCAGGATGGCGGATGTTGGGGGACAGCGGTCGGCGCAGAGGAAGTGGATCCACTGCTTTGAGAACCTGACGTCCATCCCGTTTCTCGTCGCCCTCAGTGAATACGACCAAGTCCTGGTGGAGTCGGACAACGAGAACCGGATGGAGGAGAGCAAAGCCCTGTTCCGGACCATCATCGACTACCCCTGGTTCCAGAACTCCCCCGTCATCACCTTCCTCAACAAGAAGGACCTGCTGGAGGACAATATCCTGTACTCACACATGGTGGACTACTTCCCCGAGTTCGAAGGGCCCCAGCAGGACGCCCAGGC	Homo sapiens	hg19									
GNAQ_5.chr9.80409379.80409508_tile_1	GNAQ_7.chr9.80336240.80336429_tile_1	2	chr2	132181238	132181750	+	TTAGTATTATGCAAATTGTTTTCCACAGAAATACAGTCCCTCTTGTGTATCTTCAATAGCCCACCATGGAAGGGCAGGGCGGGTGTCTAGGAGGCACAACTAGACCAGATTGTAATCCTTCAGGTTCAACTGGAGGATGGTGTCCTTGACGGCAGCAAACACAAAGCGGATATTCTCGGTGTCTGTGGCGCATGTGAAGTGGGAGTAGATAATTTGGTCACTGGGTTCAGGTCCACGAACATCTTCAGAATGAATTCTCGGGCTGCCTGGGCATCTCTCTGGGGTCCATCATATTCTGGGAAGTAGTCGACTAGATGGGAATACATGATTTTCTCCTCTGGAAGATCTTTCTTGTTTAACAACAGAATAACCGAGGAGTTCTGGAACCAGGGATACGTGATAATTGTACTAAAGAGAGCCTTGCTTTCCTCCATTCGGTTCTCATTGTCTGACT	Homo sapiens	hg19									
GNAQ_6.chr9.80343430.80343583_tile_1	GNAQ_7.chr9.80336240.80336429_tile_3	2	chr2	132181448	132181600	+	GATAATTTGGTCACTGGGTTCAGGTCCACGAACATCTTCAGAATGAATTCTCGGGCTGCCTGGGCATCTCTCTGGGGTCCATCATATTCTGGGAAGT	Homo sapiens	hg19									
GNAQ_7.chr9.80336240.80336429_tile_2	GNAQ_5.chr9.80409379.80409508_tile_2	2	chr2	132181332	132181839	-	AGGTCAGAGAGAAGAAAATGGATACACTGCTTTGAAAATGTCACCTCTATCATGTTTCTAGTAGCGCTTAGTGAATATGATCGAGTTCTCGTGGAGTCAGACAATGAGAACCGAATGGAGGAAAGCAAGGCTCTCTTTAGTACAATTATCACGTATCCCTGGTTCCAGAACTCCTCGGTTATTCTGTTGTTAAACAAGAAAGATCTTCCAGAGGAGAAAATCATGTATTCCCATCTAGTCGACTACTTCCCAGAATATGATGGACCCCAGAGAGATGCCCAGGCAGCCCGAGAATTCATTCTGAAGATGTTCGTGGACCTGAACCCAGTGACCAAATTATCTACTCCCACTTCACATGCGCCACAGACACCGAGAATATCCGCTTTGTGTTTGCTGCCGTCAAGGACACCATCCTCCAGTTGAACCTGAAGGATTACAATCTGGTCTAGTTGTGCCTCC	Homo sapiens	hg19									
GNAQ_7.chr9.80336240.80336429_tile_1	GNAQ_7.chr9.80336240.80336429_tile_1	2	chr2	132181238	132181408	+	TTAGTATTATGCAAATTGTTTTCCACAGAAATACAGTCCCTCTTGTGTATCTTCAATAGCCCACCATGGAAGGGCAGGGCGGGTGTCTAGGAGGCACAACTAGACCAGATTGTAAT	Homo sapiens	hg19									
IDH1_1_2.chr2.209113112.209113113_tile_1	IDH1_1_2.chr2.209113112.209113113_tile_1	2	chr6	7517651	7517831	+	GCGACCTACGATGATGGATTTTACCCATCCACTCACAAGCTGGGGGATATTTTTGCAGATAATGGCTTCTCTGAGGACCGTGCCAACCAGAATATTTTGGATGGTGCCATTTGGCGATTTCCACATT	Homo sapiens	hg19									
PTEN7.chr10.89717615.89717772_tile_1	PTEN4.chr10.89711893.89711900_tile_1	2	chr9	33675957	33676167	-	GTCAGAGGCGCTATGTGTATTACTATAGCTACCTGGTAAAGAATCATGTGGATTATAGACCAGTGGCACTGTTGTTTCACAAGATGATGTTTGAAACTATTCCAATGTTCAGTGGCGGAACTTGCAATCCTCAGTTTGTGGTCTGCCAGCTAAAG	Homo sapiens	hg19									
PTEN13.chr10.89720716.89720852_tile_1	PTEN4.chr10.89711893.89711900_tile_1	2	chr9	33675629	33676167	-	GTCAGAGGCGCTATGTGTATTACTATAGCTACCTGGTAAAGAATCATGTGGATTATAGACCAGTGGCACTGTTGTTTCACAAGATGATGTTTGAAACTATTCCAATGTTCAGTGGCGGAACTTGCAATCCTCAGTTTGTGGTCTGCCAGCTAAAGGTGAAGATGTATTCCTCCAATTCAGGACCCACACGATGGGAGGACAAGTTCATGTATTTTGAGTTCCCTCAGCCGTTACCTGTGTGTGGTGATATCAAAGTAGAGTTCTTCCACAAACAGAACAAGATGCTAAAAAAGGACAAAATGTTTCACTTTTGGGTAAATACATTCTTCATACCAGGACCAGAGGAAACCTCAGAAAAAGTAGAAAATGGAAGTCTATGTGATCAAGAAATTGATAGCATTTGCAGTATAGAGCGTGCAGATAATGACAAGGAGTATCTAGTACTTACTTTAACAAAAAATGATCTTGACAAAGCAAATAAAGACA	Homo sapiens	hg19									
