These reagents are shipped at room temperature. Promptly store reagents at the indicated temperature to ensure proper performance.
| Tube Qty - 16 Samples | Tube Qty - 96 Samples | Reagent | Description | Tube Cap Color |
|---|---|---|---|---|
| 1 | 4 | ST2 | Stop Tagment Buffer 2 | Red |
| 1 | 1 | TWB2 | Tagment Wash Buffer2 | Green |
| 1 | N/A* | CB | Cleanup Beads | Red |
*Cleanup Beads for 96 samples are included in Illumina Prep Dx Cleanup Beads 96 Samples
For 96 sample kits, Cleanup Beads are included in the Illumina Cleanup Beads Dx. The following reagent is shipped at room temperature. Promptly store reagents at the indicated storage temperature to ensure proper performance. For 16 sample kits, Cleanup Beads are included in Illumina Prep Dx Tagmentation Reagents 1.
| Tube Qtys | Reagent | Description | Tube Cap Color |
|---|---|---|---|
| 4 | CB | Cleanup Beads | Red |
The following reagents are shipped refrigerated. Promptly store reagents at the indicated storage temperature to ensure proper performance. Store the EBLTS stock tube upright so that the beads are always submerged in the buffer.
| Tube Qty - 16 Samples | Tube Qty - 96 Samples | Reagent | Description | Tube Cap Color |
|---|---|---|---|---|
| 1 | 4 | EBLTS | Enrichment BLT Small | Yellow |
| 1 | 4 | RSB | Resuspension Buffer | Clear |
The following reagents are shipped frozen. Promptly store reagents at the indicated storage temperature to ensure proper performance.
| Tube Qty - 16 Samples | Tube Qty - 96 Samples | Reagent | Description | Tube Cap Color |
|---|---|---|---|---|
| 1 | 4 | TB1 | Tagmentation Buffer 1 | Clear |
| 2 | 4 | EPM | Enhanced PCR Mix | Clear |
The following reagents are shipped refrigerated. Promptly store reagents at the indicated storage temperature to ensure proper performance.
| Tube Qty - 16 Samples | Reagent | Description | Tube Cap Color |
|---|---|---|---|
| 4 | SMB3 | Streptavidin Magnetic Beads 3 | Clear |
| 1 | RSB | Resuspension Buffer | Clear |
| 1 | EHB2 | Enrichment Hyb Buffer 2 | Clear |
| 1 | ET2 | Elute Target Buffer 2 | Clear |
The following reagents are shipped refrigerated. Promptly store reagents at the indicated storage temperature to ensure proper performance.
| Tube Qty - 16 Samples | Reagent | Description | Tube Cap Color |
|---|---|---|---|
| 2 | SMB3 | Streptavidin Magnetic Beads 3 | Clear |
| 4 | RSB | Resuspension Buffer | Clear |
| 1 | EHB2 | Enrichment Hyb Buffer 2 | Clear |
| 1 | ET2 | Elute Target Buffer 2 | Clear |
These reagents are shipped frozen. Promptly store reagents at the indicated temperature to ensure proper performance.
| Tube Qty - 16 Samples | Tube Qty - 96 Samples | Reagent | Description | Tube Cap Color |
|---|---|---|---|---|
| 1 | 1 | EE1 | Enrichment Elution Buffer 1 | Clear |
| 4 | 4 | EEW | Enhanced Enrichment Wash | Amber |
| 1 | 1 | PPC | PCR Primer Cocktail | Clear |
| 1 | 1 | HP3 | 2N NaOH | Clear |
| 2 | 1 | NHB2 | Hyb Buffer 2 + IDT NXT Blockers | Blue |
| 2 | 1 | EPM | Enhanced PCR Mix | Clear |
These reagents are shipped frozen. Promptly store reagents at the indicated temperature to ensure proper performance.
| Qty | Component |
|---|---|
| 4 | Illumina Unique Dual Index Dx Set A (96 Indexes), # 20050038 |
| 4 | Illumina Unique Dual Index Dx Set B (96 Indexes), # 20050039 |